[comp.dcom.sys.cisco] Brouter Bridging Problem

rjbubon@iastate.edu (Bubon Robert J) (05/15/91)

Problem Statement:
When configuring the Brouter to do bridging only, It has taken 1 hour for 
the interfaces to change from learning to forwarding. Note that we have a
bunch of DEC LanBridge 200's configured for Spanning Tree (802.1). That's
the same as Cisco's (ieee).

Here is our current configuration for the testing we're doing. Only interface's
6 and 7 are active. The rest are defaulted.

Current configuration:
!
no ip routing
!
interface Ethernet 6
no ip address
bridge-group 1
!
interface Ethernet 7
no ip address
bridge-group 1
!
ip name-server 255.255.255.255
bridge 1 protocol ieee
hostname Gateway
!
...
end

One thing I've noticed that's strange is the Spanning Tree timers.
The forward delay under the interfaces seems to have a high value that
is decrementing with time. My guess from what I've seen, is when this
timer reaches 0 forwarding will begin on the interface. A summery of the 
Spanning Tree follows.

Bridge Group 1 is executing the IEEE compatible spanning tree protocol
...
  Times:  hold 1, topology change 30, notification 30
          hello 256, max age 3840, forward delay 3840
...

Port 7 (Ethernet6) of bridge group 1 is learning. Path cost 10, priority 0
...
   Timers: message age 707687, forward delay 570, hold 0
...

Port 8 (Ethernet7) of bridge group 1 is learning. Path cost 10, priority 0
...
   Timers: message age 0, forward delay 545, hold 1
...


My questions are:
Where is this parameter being set?
Is this parameter user configurable?
Is there a protocol problem with DEC Bridge 200 Spanning tree and Cisco?
Am I on the right track for what's happening here?
Has anyone else seen this problem?


Gateway#sho ver
==========================================================================
GS Software (GS2-BF), Version 8.1(25)
Compiled Mon 05-Nov-90 00:06

System Bootstrap, Version 4.2(4)

Gateway uptime is 56 minutes
System restarted by reload
Running default software

CSC3 (68020) processor with 4096K bytes of memory.
Bridging software.
1 cBus controller.
18 Ethernet/IEEE 802.3 interface.
Environmental Controller.
64K bytes of multibus memory.
64K bytes of non-volatile configuration memory.
Configuration register is 0x181


+-----------------------+--------------------------------+-------------------+
|     IIIII  SSSS U   U | Bob Bubon - Data Sys Mgr       |                   |
|      I   S     U   U  | ISU Telecommunications         |                   |
|     I    SSS  U   U   | 95B Black                      | This space for    |
|    I       S U   U    | Ames, IA 50011                 | rent.        ._o  |
| IIIII SSSS   UUU      | Tel: 515.294.7588              |                |> |
| Iowa State University | Internet: rjbubon@iastate.edu  |                4  |
+-----------------------+--------------------------------+-------------------+