Mark_Richter@TRANSARC.COM (08/09/90)
I'm using the following: - Apple Access II 1.3.1 - Apple Super-Serial Card - Cardinal 2400 baud modem Got everything hooked up, but it appears that nothing ever gets out to the modem. In terminal mode from Access II I can't talk to the modem. +++ won't even get it's attention. Auto-dial just appears to spew the macro I'm sending into the bit bucket. The Cardinal is Hayes compatible. Do I need a null-modem cable with the super serial card? Can anyone offer some more trouble-shooting tactics that I could try to get this problem isolated? Many thanks. ------------------------------------------------------------ Mark D.Richter internet: markr%transarc.com@uunet.uu.net ------------------------------------------------------------
tomk@pro-sol.cts.com (Tom Kelly) (08/10/90)
In-Reply-To: message from Mark_Richter@TRANSARC.COM
I don't know if this will help, but here is some info on the SSC.
SUPER SERIAL CARD (SSC) SETUP SETTINGS
Recomended slots:
slot 1 for terminal use (e.g. printer)
slot 2 for communication use (e.g. modem)
Jumper Block:
for communication use label is upside down (arrow points up)
for terminal use label is right side up (arrow points down)
SW1 Dip Switch Settings:
Baud SW1-1 SW1-2 SW1-3 SW1-4 SW1-8
50 on on on off not used
75 on on off on "
110 on on off off "
135 on off on on "
150 on off on off "
300 on off off on "
600 on off off off "
1200 off on on on "
1800 off on on off "
2400 off on off on "
3600 off on off off "
4800 off off on on "
7200 off off on off "
9600 off off off on "
19200 off off off off "
Switch Settings For Communication mode:
SW1-5; SW1-6; SW1-7 are all set on
Data Parity Stop SW2-1 SW2-2 SW2-3 SW2-4
Bits Bits
7 none 1 on off off on
7 odd 1 on off on off
7 even 1 on off off off
7 none 2 off off off on
7 odd 2 off off on off
7 even 2 off off off off
8 none 1 on on off on
8 odd 1 on on on off
8 even 1 on on off off
8 none 2 off on off on
8 odd 2 off on on off
8 even 2 off on off off
Note: SW2-1 thru SW2-4 settings can be overridden by software.
SW2-5:
ON for linefeed out
OFF for no linefeed out
SW2-6:
ON for baud rates greater than 1199 baud
SW2-7:
OFF in communication mode
SW2-8:
Not used
Connector Pin Assignments
10-Pin DB-25
Header Connector Signal Name
________________________________________________________________________
1 1 Frame Ground
2 2 Transmit Data (TXD)
3 3 Receive Data (RXD)
4 4 Request To Send (RTS)
5 5 Clear To Send (CTS)
6 6 Data Set Ready (DSR)
7 19 Secondary Clear To Send (SCTS)
8 7 Signal Ground
9 20 Data Terminal Ready (DTR)