[sco.opendesktop] FAS on SCO ODT ???

vlr@dynsim2.uucp (Vic Rice) (06/15/90)

Has anybody had any success implementing the FAS async driver under
SCO ODT (UNIX 5.3.2). 

I would really like to get this working, especially since SCO's 
uugetty is broken. This forces me to muck around with enable/disable
since I have only one serial port for both incoming and outgoing
traffic.

I have an ALR PowerVEISA w/ 386 and standard 2 port com board
(Everex Magic I/O). 

Does the SCO sio driver need to be disabled (SCO doesn't have an "asy"
driver as referenced in the docs) ? If so, how ?
It keeps telling me sio must be installed and active. 
If I leave sio active and just do "make install" for the FAS stuff,
the kernel rebuilds OK. However on reboot, the system hangs during
the startup just before the info appears for the serial hardware 
( you know- int vec, DMA, base addr, etc. ). Instead of displaying
the usual, an "F1" appears on the left of the screen and its 
"deep sleep" time.
 
Any help would be greatly appreciated.
-- 
Dr. Victor L. Rice
Litwin Process Automation

jpp@specialix.co.uk (John Pettitt) (06/15/90)

vlr@dynsim2.uucp (Vic Rice) writes:

>Has anybody had any success implementing the FAS async driver under
>SCO ODT (UNIX 5.3.2). 

>I would really like to get this working, especially since SCO's 
>uugetty is broken. This forces me to muck around with enable/disable
>since I have only one serial port for both incoming and outgoing
>traffic.

>I have an ALR PowerVEISA w/ 386 and standard 2 port com board
>(Everex Magic I/O). 

FAS should work (you wil need to change the Y to N in the sio driver
entry in /etc/conf/sdevice.d to remove the sco driver).

However sco uugetty is not broken,  we have 4 trailblazers on one
of our UNIX 3.2.0 systems working just fine with dialin and out on
the same line.

There are some weird things - then device name in inittab must match
the entry in Devices (i.e no /dev or both have /dev in them) and if
you select B38400 you get B0 which causes a hangup !


-- 
John Pettitt, Specialix International, 
Email: jpp@specialix.com Tel +44 (0) 9323 54254 Fax +44 (0) 9323 52781
Disclaimer: Me, say that ?  Never, it's a forged posting !

wengland@stephsf.UUCP (Bill England) (06/17/90)

In article <1990Jun15.020958.594@dynsim2.uucp> vlr@dynsim2.uucp (Vic Rice) writes:
>Has anybody had any success implementing the FAS async driver under
>SCO ODT (UNIX 5.3.2). 
>
>I would really like to get this working, especially since SCO's 
>uugetty is broken. This forces me to muck around with enable/disable
>since I have only one serial port for both incoming and outgoing
>traffic.

   It is?  I've been using uugetty on stephsf for both logins and
   uucp traffic for about 4 months and have had no problems. 

   The functions of 'getty' that are supposed to allow uucp to work 
   are broken or not implemented however, so you must run uugetty 
   to allow logins and uucp. (Equipment 386 20Mhz, DTK with 8Megs )

>
>I have an ALR PowerVEISA w/ 386 and standard 2 port com board
>(Everex Magic I/O). 
>
>Does the SCO sio driver need to be disabled (SCO doesn't have an "asy"
>driver as referenced in the docs) ? If so, how ?

   [ Details Ommited ]

>the usual, an "F1" appears on the left of the screen and its 
>"deep sleep" time.
> 
>Any help would be greatly appreciated.
>-- 
>Dr. Victor L. Rice
>Litwin Process Automation


  This all sounds _very_ interesting.  I was considering trying to 
  get 'The Final Async Solution' running here as well but I was first 
  going to see if the com ports would run at 19.2 without my mucking
  with them.  I'll have a Telebit in a short while and will be able to
  test with that.

  Please continue to post summarys of this work!  I'm very interested
  in the details and will look it over and make suggestions if I'm
  able!


 +--------
 |  Bill England
 |  Stephen Software Systems, Inc.,   Tacoma Wa.
 |  wengland@stephsf.com              +1 206 564 2122
 |
  * *      H -> He +24Mev
 * * * ... Oooo, we're having so much fun making itty bitty suns *
  * *