[net.lan] SYTEK 20/222 reliability problems?

leo@uf-csv.UUCP (Leo Wilson [staff]) (12/25/84)

Is anyone out there in net land having problems with SYTEK 20/222
reliability?  I have had five of these babies go out on me in the
past three months.  This might not be unusual for units purchased
at about the same time, but we installed our supermuxes in July of
THIS year and I think they oughtn't be failing so soon, at least
not so close together. Five of the twenty-four boards we have is
really LOUSY if this is indicative of the reliability we can expect.

SYTEK has been pretty helpful, and they are checking on it at the 
production end.  My real question is: Is my problem with these 
strictly local, or have other people been experiencing similar 
problems?  Is there anyone out there with a big enough installation
to be doing a study of the reliability of these units independant of
SYTEK?

I'd sure appreciate some input...

Thanks in advance,
-- 
Disclaimer: The opinions expressed herein are solely those of the author.

Leo Wilson                USPS: University of Florida
akgua!uf-csv(!uf-csg)!leo       512 Weil Hall
CSNET:  leo@ufl                 Gainesville, FL  32611
AT&T:   (904)392-2371

"There are two types of aircraft: Fighters and Targets."

rjk@mgweed.UUCP (Randy King) (01/03/85)

We've had higher than normal failure rates on the S-muxen, too.  Of course,
with the 20/100's and 20/200's, "normal" meant one or two out of 75 or so,
and most of them were un-seated boards from shipment.

We have also noticed operational problems with the S-mux.  Whenever we'd
use one for people ports (human at a 20/100 calling the S-Mux) the charcter
echo got real fragmented like there were some contention problems.

So we put the S-muxen on the outgoing (wrt computer) ports for the lineprinter
system and uucp where the problem is not noticeable.  Then we noticed a bit
of DTR/DCD problems; at times sessions would close just as they were opening.

We have not investigated further; nor have we bought any more S-muxen.  I
might also add that we have not pursued it with the Sytek people either.
Other problems have been taken care of promptly.

						Randy King
						AT&T-CP@MG
						ihnp4!mgweed!rjk

jeffm@tektronix.UUCP (Jeff Mulick) (01/03/85)

In reply to the questions on Sytek 20/222 reliability problems
from Leo Wilson (...uf-csv!leo)

Yes, there are others that are unhappy with the Sytek 20/222 reliability.

And, yes, there is an independent study  being conducted right now! In fact,
we are looking for opinions on all of their products, not just the S-mux.

The Sytek Network Users Group (SNUG) coordinates the gathering of this type
of information. Please read the following article announcing our upcoming
meeting for further information.


--------------------------------------

Jeff Mulick
Computer Resource Department   DS 50/454
Tektronix, Inc.
P.O. Box 500
Beaverton, OR  97077

UUCP:		...decvax!tektronix!jeffm
ARPA:		jeffm.tek@rand-relay
CSnet:		jeffm@tektronix.csnet
MaBell:		(503) 627-5007