max@lgc.lgc.com (Max Heffler @ Landmark Graphics) (02/11/90)
I have successfully used the acu1 port for outbound traffic from my Telebit on a Compaq 386/25 running 386/ix 2.0.2 with the x5 update. I have not been successful with the getty on ttyd1. When I set it up per the documentation, the modem will answer, but ps -ef shows getty still running but no login prompt is offered, and the caller appears hung. My /etc/conf/init.d/asy is: # Telebit Trailblazer on ttyd1 01:2345:respawn:/etc/getty -t 60 ttyd1 TB8-19200 I performed idmkinit and tested it successfully using telinit q My Dialers has: tbfast =W-, "" A\pA\pA\pA\pA\pT OK ATx3s0=0s64=1s50=255DT\T FAST-\c-FAST tbinit =W-, "" A\pA\pA\pA\pA\pT OK ATs51=254 OK My Devices has: ACU acu1 - 9600 tbfast \T ACU acu1 - 19200 tbfast \T ACU tbinit - 19200 tbinit \T and I successfully dial on on acu1, including cu and uucp. My gettydefs has: TB8-19200# B19200 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IXON IXANY ISTRIP ECHO EC HOE ECHOK ICANON ISIG CS8 CREAD # B19200 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IX ON IXANY ISTRIP ECHO ECHOE ECHOK ICANON ISIG CS8 CREAD #login: #TB8-2400 TB8-2400# B2400 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IXON IXANY ISTRIP ECHO ECHO E ECHOK ICANON ISIG CS8 CREAD # B2400 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IXON IXANY ISTRIP ECHO ECHOE ECHOK ICANON ISIG CS8 CREAD #login: #TB8-1200 TB8-1200# B1200 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IXON IXANY ISTRIP ECHO ECHO E ECHOK ICANON ISIG CS8 CREAD # B1200 HUPCL OPOST ONLCR TAB3 BRKINT IGNPAR IXON IXANY ISTRIP ECHO ECHOE ECHOK ICANON ISIG CS8 CREAD #login: #TB8-19200 Does anybody have any clues as to why the getty does not give a login prompt and or what methods are there for testing further the operation on the Compaq when the login prompt is not produced? Help... Thanx in advance -- Max Heffler internet: max@lgc.com Landmark Graphics Corp. uucp: ..!uunet!lgc!max 333 Cypress Run, Suite 100 phone: (713) 579-4751 Houston, Texas 77094
terry@pride386.UUCP (Terry Lyons) (02/13/90)
In article <208@lgc.lgc.com>, max@lgc.lgc.com (Max Heffler @ Landmark Graphics) writes: > > Does anybody have any clues as to why the getty does not give a login prompt > and or what methods are there for testing further the operation on the Compaq > when the login prompt is not produced? Help... well they moved one of the registers in 5.0 you probably have the modem set for Q4 which will fight with getty make Q6 ala ATQ6......&W also register S53 is S131 in 5.0 so if your setting S53 ( to track DCD) your modem just eats the instruction and tries to force DCD true!!!! so you can call out but not in hope this helps this drove me crazy for 2 weeks till I found out that S53 does not exist terry @ ...pride386!