paine@rust.enet.dec.com (Willy Paine) (03/14/90)
I am using Telebit T2500 on rotating gettydefs and I thought I can not
put flow control lock on 19200 because ix/386 does not have full flow
control. I am using TB on bidirectional (include newsfeed).
If you use flow control lock, I would like to look the setup in TB eeprom.
willy
ok, now /etc/gettydefs
VSH# B19200 CS8 SANE HUPCL TAB3 IXANY #B19200 CS8 SANE HUPCL TAB3 IXANY #connection via Hayes V-Series V.42\r\nlogin: #VSH
HSTH# B19200 CS8 SANE HUPCL TAB3 IXANY #B19200 CS8 SANE HUPCL TAB3 IXANY #connection via USR Courier HST\r\nlogin: #HSTH
PEPH# B19200 CS8 SANE HUPCL TAB3 IXANY #B19200 CS8 SANE HUPCL TAB3 IXANY #connection via Telebit Trailblazer\r\nlogin: #PEPH
Now - I am using a Computone Intelliport, and here is my /etc/ic_control file:
Note** ttyi00 and ttyi01 are the V-Series which are locked at 9600 baud since
they don't want to work on a regular basis with them locked at 19200.
The other two ports are the HST and PEP modems.
ttyi00:
buffers:
receive%=50
communications:
baud=9600
stopbits=1
bits=8
parity=none
handshake=busyready
addcr=no
ttyi01:
=ttyi00
ttyi02:
buffers:
receive%=50
communications:
baud=19200
stopbits=1
bits=8
parity=none
handshake=busyready
addcr=no
ttyi03:
=ttyi02
hope this helps - larry
larry@nstar.UUCP (Larry Snyder) (03/14/90)
In article <9003140025.AA28768@decwrl.dec.com>, paine@rust.enet.dec.com (Willy Paine) writes: > > > I am using Telebit T2500 on rotating gettydefs and I thought I can not > put flow control lock on 19200 because ix/386 does not have full flow > control. I am using TB on bidirectional (include newsfeed). I lock my modems all at 19200 (except the hayes V-Series which I lock at 9600 baud) and let the modem stepdown to the connect baud rate.. I have the latest rfmail from Finland in /usr/public/uploads on nstar - larry -- The Northern Star Public Access Unix Site, Notre Dame, Indiana USA uucp: iuvax!ndmath!nstar!larry internet: larry@nstar USR HST 219-287-9020 * PEP 219-289-3745 * Hayes V9600 219-289-0286