mussar@bcars53.bnr.CA (G. Mussar) (12/08/90)
I have uploaded to SIMTEL20: pd1:<msdos.modem> DLM120.ZIP Data Line Monitor. Makes PC a DATASCOPE This program monitors both sides of an asynchronous data communications line using a passive "Y" cable which connects to the monitored devices and BOTH comm ports (COM1 and COM2). Up to 32K events (data characters or hardware signal changes) may be buffered and reviewed. Monitors RTS, DTR, CTS, DSR, CD and RI. Handles line speeds from 110 to 19200. -- ------------------------------------------------------------------------------- Gary Mussar |Bitnet: mussar@bnr.ca | Phone: (613) 763-4937 BNR Ltd. | UUCP: ..uunet!bnrgate!bcars53!mussar | FAX: (613) 763-2626