[comp.sys.zenith] zenith z-19 terminal help needed

lfischer@pluto.dss.com (Larry Fischer) (02/22/91)

I tried to reply to someone but it bounced.  My terminal is a Z-19.
I am looking for the dip switch definitions.

Thanks,
Larry

mandell@mozart.helios.nd.edu (Dan Mandell) (02/25/91)

I have the manual for the Z19 in front of me.  
sw401:
0-3  Baud Rate
4    0=no parity, 1 = parity
5    0=odd parity, 1=even
6    0=normal parity, 1=stick parity
7    0=half duplex,1=full parity
        0 is up; 1 is down
 
Baud    0  1  2  3
1200    1  0  1  0
2400    0  0  0  1
9600    0  0  1  1
 
sw402:  push all switches to 0 for starters
   switch 5 is 0=Zenith mode; 1 = ANSI mode
 
If you need other info ,  ask.