it1@ra.MsState.Edu (Tim Tsai) (02/23/91)
Hello.. I'm having a little problem with a Zenith AT running Novell's
workstation software.. The computer is setup as follows:
Zenith 286 machine (probably a model 248, with a very large case and
backplane (sp?) design where the majority of the motherboard sits on
one card. This machine is pretty old, but has performed
flawlessly for a number of years without any major compatibility
problem)
512K of memory
PC Dos 3.3 with minimal config.sys and autoexec.bat (files=20,
buffers=20, prompt=$p$g, path=, and a packet driver. That's it)
Zenith EGA Card with 256K of memory (Which emulates EGA on a Hercules monitor)
40 Meg MFM drive with controller.
1 1.2 Meg floppy drive.
1 Serial port set at COM1: (IRQ = 4, Base address = 0x3f8h)
1 Parallel port set at LPT1:
Everex Sppedlink PC Ethernet board (8 bit)
IRQ = 2
Base address = 0x360h
High performance mode
No boot prom
64K of RAM
Everex's FTP driver, which is based on Clarkson's packet driver.
IRQ = 2
Packet Int. # = 0x60h
Base address = 0x360h
IPXP (IPX for packet driver)
NET3 (latest version I believe, from Novell)
The NET3 program locks up whenever I try to run it (after running the
packet driver and IPXP). Any ideas?
BTW, CUTCP and NCSA Telnet works just fine with this setup.
Thanks in advance for any help...
--
"Abandon all hope, ye who press enter here." - Somewhere in Usenetbdahlen@zephyr.cair.du.edu (Robert L. Dahlen - U. of Denver USA=) (02/26/91)
In article <it1.667305672@ra> it1@ra.MsState.Edu (Tim Tsai) writes: > > Hello.. I'm having a little problem with a Zenith AT running Novell's > workstation software.. The computer is setup as follows: > > Zenith 286 machine (probably a model 248, with a very large case and > 512K of memory > PC Dos 3.3 with minimal config.sys and autoexec.bat (files=20, > buffers=20, prompt=$p$g, path=, and a packet driver. That's it) > Zenith EGA Card with 256K of memory (Which emulates EGA on a Hercules monitor) > 40 Meg MFM drive with controller. > 1 1.2 Meg floppy drive. > 1 Serial port set at COM1: (IRQ = 4, Base address = 0x3f8h) > 1 Parallel port set at LPT1: > > Everex Sppedlink PC Ethernet board (8 bit) > Everex's FTP driver, which is based on Clarkson's packet driver. > IPXP (IPX for packet driver) > NET3 (latest version I believe, from Novell) We use a similar setup on Z248's, but are using Arcnet and 3Com and Lanmaster ethernet cards with no problems, for whatever it's worth. -- ------------------------------------------------------------------- Robert L. Dahlen - Director, Information Systems & Technology University of Denver - Denver, Colorado 80208 (303) 871-4385 INTERNET:bdahlen@du.edu BITNET:bdahlen@ducair