[comp.sys.proteon] p4200's and Dowty CSUs interfacing on T1 link

wendy@BRL.MIL ("Wendy A. Winner ", VLD/VMB) (08/15/89)

All,

	We have been in the process of installing a dedicated
point-to-point T1 link between organizations using Dowty T1 CSUs and
Proteon p4200's. In the past month, we have experienced numerous
problems with both the CSUs and the circuit.

	We have booted both Proteon p4200 gateways at each end location
without incident and each gateway's T1 RS449 interface has come up with
the CSU in a local loopback state.  We have also checked all RS449
cables for continuity.  We are 99.5% certain the problem does not lie
with the gateways.

	Dowty is fairly confident on the settings for their CSUs,
however, they are not 100% confident about setting for the Density Mode
(FCC Part 68 or 62411) and the Sync Data Mode (Normal or Inverted).
Please refer to the chart below for the configurable list of parameters.

	Our DSU/CSU is running firmware release 2.2 (required to be
compatible with the telephone company's smart jack) and the other end is
running an older rev.

	We would appreciate any suggestions on the Dowty CSU and Proteon
p4200 interface.

Thanks,
Wendy Winner
(301) 278-6655


        Configuration Information for Dowty CSU, Model 7055060
                 Firmware Releases 2.1 & 2.2
            
            -----------------------------------
            |   Parameter          Setting     |
            +----------------------------------|
            |                                  |
            |   DTE Rate         1344000 bps   |
            |    Format         306 to T1 D4   |
            |     Mode           Sync to AMI   |
            |   Interface           RS422      |
            | Density Mode       FCC Part 68   | or 62411?
            |    Timing           Internal     | (Timing is repeater at remote
	    |                                  |  to provide the clock.)
            |   KP Alive       2 - Framed once |
            |  Remote unit       Compatible    |
            |Line Build Out           0        | We've also tried 7.5db.
            |Remote Loop Opt       Enable      |
            | SY Data Mode         Normal      | or Inverted?
            |  Sync Clock         Give Both    |
            |   Sync DSR             On        |
            |   Sync CTS             On        |
            |   Sync LSA             On        |
            | Sync Diagntc           Off       |
            -----------------------------------

ron@HARDEES.RUTGERS.EDU (Ron Natalie) (08/15/89)

Make sure that all your Dowty modems are running 2.X firmware.  The version
1 stuff has bugs in it that keep it from working with Cisco, so it probably
breaks with Proteon as well.