[comp.sys.xerox] problem with 6085

chris2@cosmo.UUCP (Christoph Heeb) (12/05/89)

I have a problem with my Daybreak running VP 1.2. The following happend:
After booting the system th error code 7511 occured. In hope that I only
had to install the File check software I began my word, but just in the
moment I tried to install the SW I was toled to scavenge the Volume first.
So I did the physical volume scavenge as there was no phys. vol.existing.
It finished with no problems (damage detected, log file built!)
At this moment I used the order: Describe phys.vol.! Only the scavenger-
volume was listed. There is no user Vol. to find. I remembered that there 
are some possibilities with the Debugger SW-tool to define the lost
2nd once existing Volume (Mugger or Disk editor).
Now I only have a 20Mb Disk and Tajo can only be installed on a 40 or    
larger Disk. Alos sometimes when I make "Describe phys.vol." I get the
message: uncaught signal=(22320B,3),msg=(3,22320B,3,0 ......
Then I have to boot the system for any next action.

Anyone able to give me some help or information to my problem??
thanks
chris heeb
So I did the physical volume scavenge as there was no phys. vol. existimn