tmiller@chaos.cs.brandeis.edu (Todd Miller) (04/13/91)
New Pro 350 owners are so worried about the error codes I have reproduced the most common ones here. These are taken from the P/OS handbook. Note that unless you want to buy new components all you can do is reseat connections! Code Problem area Corrective Action 000100 P/OS keyboard handler 1: Check cables and connections 2: Reseat option modules in card cage. 3: Reset all IC's in sockets on system module. 5: Replace system module 6: Reload Operating system. 000200 Terminal driver [deleted] 000300 Executive/general If error occured on first access of RX or RD subsystem, check that subsystem is in order: 1: Check cables and reseat controller in card cage 2: Replace Drive 3: Replace RX or RD subsystem controller If error not found on first access of mass storage, goto 000200 corrective action. 000400 System startup processing 000500 Terminal driver (video and printer port) Second line Error Codes 000000 IOT in system state 000001 Stack overflow or cannot install task CBOOT 000002 Trace Trap or breakpoint or cannot spawn task CBOOT 000003 Illegal instruction trap or cannot spawn task CBOOT 000004 Odd address or other trap to 4 000005 Segment fault 000006 A task on P/OS without a parent aborted 000007 EMT trap or required file not found 000010 TRAP trap