[comp.sys.ibm.pc.rt] SNA SDLC error...

sean@adelie.Adelie.COM (Sean Conway) (05/31/89)

Here we go again... I'm configuring SNA for my second RT (model 135) running
AIX 2.2.1 and have run into an apparent software defect.  The attempt
to start an "SDLC-RS232C" attachment fails.  IBM thinks it is a SNA
configuration problem while I disagree.  I've sucessfully installed the first
RT (model 125) running AIX 2.2.0 and configured SNA.  Both RTs "share" the
same modem via a line sharer and talks to the same 3705 controller, hence,
both RTs are configured the same in terms of physical, control point, etc..
with the exception of things like station address, LU2, etc...

First, the error I "see" reported by "errpt" tells me that the AIX software
cannot even communicate with the multiprotocol board (it appears to be an
microcode error).  I'm very confident I've configured the machine properly in
terms of DMA channels, adapter slot location, addresses, diagnostics,
devices (mpdp, sdlcll0), etc...

I definitely know another RT site (model 135, AIX 2.2.1) had microcode
problems also and required a patch.  IBM has not heard of such a patch.
Anyone out there know anything?  I included the ouput from the "errpt" so
you can see what I'm talking about (see below signature)..

ADthanksVANCE, sean

Sean Conway
Systems Manager
Adelie Corporation
Cambridge, MA 02140

{..harvard!adelie!sean}


				ERROR LOG REPORT

Error log: /usr/adm/ras/errfile

-------------------------------------------------------------------------------
DateTime            Class           Subclass        Type      Device  Cause
Wed May 24 03:22:20  Communications  SDLC_LLC        Perm              Software

Cause=Adapter_Error 
Error=Open_failed 
Return_Code=DH_Adapter_microcode_IPL_error 
LLC_IODN_(hex)=13D4 	LLC_IOCN_(hex)=0403 
LLC_Profile_Name=
PLC_Profile_Name=rabbitpl 

-------------------------------------------------------------------------------
Date/Time            Class           Subclass        Type      Device  Cause
Thu May 25 22:55:45  Communications  SDLC_LLC        Temp              Software

Cause=User_Interface_Error 
Error=Invalid_Path 
Path_ID=0169 
LLC_IODN_(hex)=13D4 	LLC_IOCN_(hex)=0403 
LLC_Profile_Name=
PLC_Profile_Name=rabbitpl