dave@wor-mein.UUCP (Dave Axness) (08/28/89)
Does anyone know how to patch uucico to run at 19200. I need it for both Ultrix 1.2 and 2.2 in case there's a difference. thanks, Dave Axness Quantum Medical Systems, Inc Issaquah, WA uunet!wor-mein!dave
grr@cbmvax.UUCP (George Robbins) (08/29/89)
In article <1535@wor-mein.UUCP> dave@wor-mein.UUCP (Dave Axness) writes: > Does anyone know how to patch uucico to run at 19200. I need it for both > Ultrix 1.2 and 2.2 in case there's a difference. The general form is (as super user): su cd /usr/lib/uucp (may be /var... on later releases) cp uucico uucico.backup echo "spds?W 0t19200 0t14" | adb -w uucico This replaces the 50 baud entry in the speed table with one for 19200 baud. Note that the Ultrix 3.x uucp already has entries for 19200 and 38400 baud. -- George Robbins - now working for, uucp: {uunet|pyramid|rutgers}!cbmvax!grr but no way officially representing arpa: cbmvax!grr@uunet.uu.net Commodore, Engineering Department fone: 215-431-9255 (only by moonlite)