[comp.sys.transputer] MAXBUS to Transputer Link Interface

eederavi@pyramid.swansea.ac.uk (Farzin Deravi) (10/27/88)

We are considering interfacing a DATACUBE image processing system
to a MEIKO Computing Surface. This may involve the development
of a VME card that at one end has a MAXBUS interface and at the
other end has a link interface. MAXBUS specification is public domain
according to our supplier and I was wondering if someone may have
gone down this route before. Could you please mail me any information
you may have that could help us in this project.
Many thanks.


         			   - - - - - - - - - - - - - - - - - - - -
Farzin Deravi, 			 | UUCP  : ...!ukc!pyr.swan.ac.uk!eederavi|
Image Processing Laboratory,	 | JANET : eederavi@uk.ac.swan.pyr	  |
Electrical Engineering Dept.,    | voice : +44 792 295583                 |
University of Wales,	 	 | Fax	 : +44 792 295532                 |
Swansea, SA2 8PP, U.K.		 | Telex : 48358                          |
 			 	   - - - - - - - - - - - - - - - - - - - -