NU021172@NDSUVM1.BITNET (Marty Hoag) (10/03/89)
In response to my query here or on the VMSHARE conference I received a note from a person at the University of Toledo saying that he had the same problem and got a zap to fix it from IBM Level 2. He indicated there was some reluctance to apar the problem... His incident was closed on 9/27/89. The zap U of Toledo got was to ISTTSCUF with UV38648 on worked here too! IBM Level 2 called after we had tested it (I was only at Sev 2) and said they were about to give me the same zap. They promised me to APAR the problem internally. Since VTAM 3.1.0 is current only through the end of October the timing is important. Maybe they didn't realize how many of us laggards there are... ;-) One other tidbit we ran into. The 3174-11L Token Ring 16Mbps adapter card (9351) has a ground lug for the shield of the patch cable. We found that some cables we bought from a third party, while having the shield and a place to attach the shield to the ground lug, did not work (symptom was 0880 errors and the adapter wouldn't open). This happened on two different 3rd party cables. Using the supplied short cable connected to a patch cable worked. The same third party cables worked ok on other devices and some of the TRN adapters (like the 3174-03R/9350) don't even have the grounding connection. This is our first token ring network so the answer to this may be obvious to others... But it may be wise to stick with the trn cable that comes with the 11L (or 9351) and just extend it with a patch cable if necessary... ;-) Marty