SSBSC@ECUVM1.BITNET ("Brad S. Carson") (06/18/91)
Hello, due to circumstances beyond my control we at East Carolina Univ-
ersity have to provide an EP connection to our RSCS V2.3 system. However
when we start the link and the user dials in RSCS always gets an I/O error
and drains the line before the /*SIGNON card is received. The message I
receive is
DMTNPT070E I/O error on link FWCRJE 044 SIOCC 0 CSW 000CC620 0C000001
SENSE 00 CCW 020CC620 20000002
The configuration is:
VM/HPO 5.0
RSCS 2.3.0
EP Release 4
3725 Model 1
Black Box 208 A/B modem
RSCS CONFIG contains:
LINK FWCRJE MRJE 044 * * 4 FIFO 4 * * AST
PARM FWCRJE SYSTEM=HOST ITO=2 OPT=NO PASS=????????
Line 044 is ATTACHed via an ATTACH statement in PROFILE GCS.
The PEP gen for the 3725 contains:
DIAL21 GROUP DIAL=YES,
CHNPRI=HIGH,
CLOCKNG=EXT,
CODE=EBCDIC,
CU=2701,
DUPLEX=HALF,
LNCTL=BSC,
SPEED=4800,
PAD=NO,
TYPE=EP
P21LN33 LINE ADDRESS=(33,44-0),
TERM=2780
All I can say is HELP!!! I can't really find anything wrong, and the local
IBM office doesn't have anybody who can spell EP DIAL support let alone EP.
Sorry for the cross posting of this mail.
------------------------------------------------------------------------
Brad S. Carson Bitnet : SSBSC@ECUVM1.BITNET
Systems Programmer (MVS & VM) Internet: ??Not quite yet??
East Carolina University NASCOMM : CarsBraS
Austin 108 Bellnet : (919) 757 - 4346
Greenville, NC 27858