[comp.protocols.misc] Emulex Terminal Servers

sysprga@sahiways.gov.au (Trevor Bate) (03/14/89)

HELP! Is anyone using Emulex Performance 4000 terminal servers?

We have two and they work perfectly well as long as we don't want
to connect to a PDP 11/44 running RSX-11M Plus V3.0. Has anyone
else experienced these, or other problems with these terminal
servers?

The P4000 seems to recoginize the PDP, shows it as a valid service, but
gives an error when you attempt to connect to it.

Trevor Bate,
Highways Department, South Australia.
(08) 343 2021
BATE@sahiways.gov.au

system@vaxa.uwa.oz (Systems Programmer, VAXA) (04/17/89)

In article <486@sahiways.gov.au>, sysprga@sahiways.gov.au (Trevor Bate) writes:
> HELP! Is anyone using Emulex Performance 4000 terminal servers?
> 
> We have two and they work perfectly well as long as we don't want
> to connect to a PDP 11/44 running RSX-11M Plus V3.0. Has anyone
> else experienced these, or other problems with these terminal
> servers?
> 
> The P4000 seems to recoginize the PDP, shows it as a valid service, but
> gives an error when you attempt to connect to it.
> 
 IF you have 1.02 of the server image, you turn on 'EMULEX option 1'
( disable LAT packet checking) and it all workes... We have been testing them
at WA Dept of Agriculture for a month or so. So far, so good.

Paul Repacholi
(09) 368 3438