sob@harvisr.harvard.edu (Scott Bradner) (10/24/90)
oops - a few things about the router testing posting the correct name for the "Proteon RIG" is the "Proteon XP 20000" the "fld" on the table is the "raw" rate (i.e. frames input at the maximum rate that the test equipment can produce) and here is the delay values (I seem to have missed one of the cisco cases - sorry) ------------------------------------------------------------------- 3com NETBuilder - delay size min avg max 64 .2 .21 .25 128 .2 .21 .25 256 .2 .21 .25 512 .2 .21 .25 1024 .2 .21 .25 1518 .2 .21 .25 BBN T20 - delay size min avg max 64 .2 5 10 128 .2 5 10 256 .2 5 10 512 .2 5 10 1024 .2 5 10 1518 .2 5 10 NSC between - delay size min avg max 64 .41 .41 .42 128 .5 .5 .6 256 .5 .5 .6 512 .5 .55 .6 1024 .5 .55 .6 1518 .5 .55 .6 NSC - within - delay size min avg max 64 .21 .21 .21 128 .22 .22 .22 256 .24 .24 .24 512 .25 .25 .25 1024 .25 .25 .25 1518 .25 .25 .25 Novell NetWare - delay size min avg max 64 .5 .55 .6 128 .55 .58 .62 256 .6 .625 .65 512 .62 .65 .7 1024 .78 .8 .82 1518 .8 .85 .9 Timeplex TIMELAN - delay size min avg max 64 .15 .15 .15 128 .15 .15 .2 256 .18 .18 .25 512 .2 .2 .3 1024 .2 .2 .3 1518 .28 .28 .28 Wellfleet - between - delay size min avg max 64 .4 .4 .41 128 .41 .41 .42 256 .42 .42 .42 512 .5 .5 .51 1024 .59 .59 .6 1518 .65 .65 .68 Wellfleet - within - delay size min avg max 64 .28 .28 .28 128 .28 .28 .28 256 .28 .28 .28 512 .28 .28 .28 1024 .28 .28 .28 1518 .28 .28 .28 cisco - within - delay size min avg max 64 .8 .8 .8 128 .8 .8 .8 256 .8 .8 .8 512 .8 .8 .8 1024 .8 .8 .8 1518 .8 .8 .8