edb@fai.UUCP (Edward Bunch) (03/21/89)

In article <5950@hurratio.tde.lth.se> mac@tde.UUCP () writes:
>Help wanted with Aufs
>However when trying to login something goes wrong.
>01831* 12:32:40 02/22/89 Recorded terminated inferior Aufs PID 1834
>01831* 12:32:44 02/22/89 process 1834, session 1 was terminated on signal 11
>01831* 12:32:44 02/22/89 woops: we just dumped core on pid 1834

I had this same problem with Aufs on my Sequent. When I compiled it up for
debugging the problem went away. Apparently, the Sequent compiler optimizes a
little too much for Aufs. I removed the optimization and it works.