[comp.os.vms] area routing lossage

AWalker@RED.RUTGERS.EDU (*Hobbit*) (07/09/87)

We've just started playing with area routers, and cannot seem to make them
talk to each other.  Having installed the full-function keys and all, I bring
one system [the 785] up as 1.13, and a microvax up as 2.1.  They are both on
the same ethernet; the circuits {q,u}na-0 both on with a cost of 1.  Show
circuit in NCP shows that they see each other.  However DCL show net does not.
What seems particularly odd is that show net (and in NCP, sho exec area status)
shows the cost of the local area as being 1023, i.e. unreachable.  It
should, of course, show the cost of the local area as being 0, and the
cost of the adjacent area as being 1.  Using an Ethernet monitor to look
at the routing traffic, the level 1 routing message from the 785 doesn't
show node 0 (default area router) as being reachable.  It looks like somehow
area routing isn't quite turned on.  As far as we can see in the documentation,
all you need to do to enable area routing is set the node type to area, and 
have at least one circuit to an adjacent area.  Are we missing something?
All the other things we could think of [lines, circuits, etc] seem properly
configured and on.

_H*  and Chuck Hedrick
-------