[comp.os.vms] RM03 on a 750?

shaw%MV4.UNCA.AdhocNet.CA@UNCAEDU.BITNET (04/16/88)

        I am forwarding this for a colleague who does not listen to info-vax.
        Please send any replies to:

        TSHAW@UNCAEDU.bitnet

********************************************************************************

   Re: Dilog 218

     To: Whom it may concern;

        I am the proud owner of a Dilog 218 disk controller and several
        SMD disk drives which once lived on a PDP-11/60. The controller and
        drives work fine. We have finally decided to retire the PDP and the
        idea of using the drives on our VAX has been considered. We own a nice
        little VAX 11/750 which has 1 gigabyte of DU type drives on it. The
        question remains, "Can we use the Dilog 218 on our VAX Unibus and if so,
        what driver do I use?" The Dilog 218 emulates an RH11/RM03
        configuration on the PDP 11/60 Unibus. Has anyone tried using an RH11
        on a VAX Unibus and if so how?

                                                 Signed
                                       Too cheap to buy another RA-81

tshaw@UNCAEDU.BITNET (04/20/88)

        I am forwarding this for a colleague who does not listen to info-vax.
        Please send any replies to:

        Terry Shaw
        Faculty of Medicine
        University of Calgary        TSHAW@UNCAEDU.bitnet

        (our info-vax feed has been very erratic lately)

********************************************************************************

   Re: Dilog 218

     To: Whom it may concern;

        I am the proud owner of a Dilog 218 disk controller and several
        SMD disk drives which once lived on a PDP-11/60. The controller and
        drives work fine. We have finally decided to retire the PDP and the
        idea of using the drives on our VAX has been considered. We own a nice
        little VAX 11/750 which has 1 gigabyte of DU type drives on it. The
        question remains, "Can we use the Dilog 218 on our VAX Unibus and if so,
        what driver do I use?" The Dilog 218 emulates an RH11/RM03
        configuration on the PDP 11/60 Unibus. Has anyone tried using an RH11
        on a VAX Unibus and if so how?

                                                 Signed
                                               Too cheap to buy another RA-81


        Doug Hamilton
        Faculty of Medicine
        University of Calgary
        Calgary, Alberta, Canada                P.S. we are running VMS V4.6.


-------