[comp.sys.sun] problems with cpio

monty%tartarus@gargoyle.uchicago.edu (Monty BSD) (12/01/88)

we've been having a problem with cpio and our tape drive.  when we run
cpio with the -B option (5120 blocksize), we get the messages:

	vmunix: xt0: lost interrupt
	vmunix: xt0: bad command synchronization

and cpio aborts.  its takes a while for these messages to appear; cpio
starts out working fine, but eventually bombs.  the problem only occurs
with the -B option.  sun came to look at the problem and, before we had
isolated the -B option as the cause, thought that it was a bad controller,
but replacing it didn't solve the problem.  has anyone seen this problem
before ?  is it a bug in cpio ?  we're running sunOS 4.0 on a 4/280S with
a fujitsu GCR 9 track drive on a Xylogics 472 controller.

thanks in advance,
   monty
   univ of chicago/biological sciences division
   internet: monty@tartarus.uchicago.edu

eap@bu-it.bu.edu (Eric Pearce) (12/16/88)

monty%tartarus@gargoyle.uchicago.edu (Monty BSD) says:
>we've been having a problem with cpio and our tape drive.  when we run
>cpio with the -B option (5120 blocksize), we get the messages:
>
>	vmunix: xt0: lost interrupt
>	vmunix: xt0: bad command synchronization
>
 [ stuff deleted ]
>before ?  is it a bug in cpio ?  we're running sunOS 4.0 on a 4/280S with
>a fujitsu GCR 9 track drive on a Xylogics 472 controller.

We were getting similar errors on 3/280 with 2 Xylogics 451's.  They went
away after we put the Xylogics 472 controller before (in a lower slot
number) the 2 disk controllers.  If you have your 472 after the disk
controller, try exchanging them. I'm not sure why you would get them only
with "the -B option" ... we produced ours while using '/etc/dump'.

 -e

Eric Pearce
Boston University Information Technology
111 Cummington Street
Boston, MA 02215
eap@bu-it.bu.edu
617-353-2780 (voice)
617-353-6260 (fax)

 UUCP !harvard!bu-cs!bu-it!eap  ARPANET eap@bu-it.bu.edu  CSNET eap%bu-it@bu-cs
 JNET jnet%"ep@buenga" BITNET iteap@buacca or ep@buenga