[comp.sys.sun] CDC & 753 Xylogics

dclassen@swift.bcm.tmc.edu (David Classen) (03/30/89)

I have read in this news group that this combination ( CDC 1.2 GB ) works
well.  I have however had a hard time getting mine installed. The problem
I have is:

My Sun 4/260 crashes with a an eror message of

	    spurious VME interupt at processor level 5 VME level
            3, VME vector 0xffffffff

this happens when I try to tar one file system to another or when I run
suninstall and it's trying to load the usr partition.

I can make file systems and look at it with format.  My configuration is:

	  4/260-32 run SunOS 4.0
	  SCSI tape
	  Xylogics 450/451  with 2 micropolis 256 MB drives
	  Xylogics 753 with CDC Sabre 1.2 GB drive.

	Any help would be greatly appreciated.

Thanks
David Classen
dclassen@swift.bcm.tmc.edu
(713) 798 3738
Molecular Biology Information Resource

eap@bu-it.bu.edu (Eric Pearce) (04/21/89)

dclassen@swift.bcm.tmc.edu (David Classen) says:
>I have read in this news group that this combination ( CDC 1.2 GB ) works
>well.  I have however had a hard time getting mine installed. The problem
>I have is:
>
>My Sun 4/260 crashes with a an eror message of
>
>	    spurious VME interupt at processor level 5 VME level
>            3, VME vector 0xffffffff
>
>this happens when I try to tar one file system to another or when I run
>suninstall and it's trying to load the usr partition.

We have 4/280 that prints that message out every 10-15 minutes or so, but
it doesn't crash.  I always thought it had something to do with having a
second ethernet interface, since it's usually followed by the the famous
"ie1: spurious interrupt" message.  We have a Xylogics 451, a SCSI 1/4"
tape, a 32 meg memory card, an ALM-2 and a TAAC board.  Field service gave
the generic "it's fixed in the next rev" line, but I've heard it could be
caused by the VME to Multibus adapter cards used by ie1 and the 451.  The
rate of the error messages does seem to increase when the network
interface is used, such as during a remote dump.  We also tried upgrading
to the newest rev cpu (rev 14?) with no change.  I would assume they would
pay more attention to you if it actually crashed your system, instead of
just wasting console paper.  

  -e

 Eric Pearce                                   ARPANET eap@bu-it.bu.edu
 Boston University Information Technology      CSNET   eap%bu-it@bu-cs
 111 Cummington Street                         JNET    jnet%"ep@buenga" 
 Boston MA 02215                               UUCP    !harvard!bu-cs!bu-it!eap 
 617-353-2780 voice  617-353-6260 fax          BITNET  ep@buenga

phil@bashful.cgrg.ohio-state.edu (Phil Ritzenthaler) (04/27/89)

David Classen <dclassen@swift.bcm.tmc.edu>:
> My Sun 4/260 crashes with a an eror message of
> 
> 	    spurious VME interupt at processor level 5 VME level
> 	    3, VME vector 0xffffffff
> 
> this happens when I try to tar one file system to another or when I run
> suninstall and it's trying to load the usr partition.

NOTE:  TO ANYONE INSTALLING A XYLOGICS 753 WHILE RETAINING THEIR 451 CONTROLLER

Xylogics had a MAJOR BUG in their firmware!!!  I was experiencing THE SAME
EXACT error message as Dave did.  The solution is to RETURN your board to
the company you purchased it from and have them send you the LATEST REV
level from Xylogics (date 27-Mar-1989 (?)).  

After installing the new board, I am running:
	4/280 32M memory
	SCSI tape
	Xylogics 451 with 1 Hitachi DK815-10
	Xylogics 753 with 2 Fujitsu M2372K

with no problems (knock on wood . . .).


Phil Ritzenthaler   Advanced Computing Center for the Arts & Design (ACCAD)
Systems Manager     The Ohio State University
                    UUCP: ...!{pyramid,killer}!grumpy.cgrg.ohio-state.edu!phil
                    ARPA: phil@grumpy.cgrg.ohio-state.edu