mitch@hplabs.hp.com (Mitchell S. Gorman) (12/28/89)
I walked in this AM, to find one of my systems locked up. An 'L1-A' combo did NOT clear the problem; checking my ethernet card revealed that the diag lights were behaving very strangely. This is the second time that this has occurred. The only thing that will clear it is either a power cycling, or a flick of the reset switch on the back of the ethernet card. The error message that dmesg reports is as follows: mt: trap address 0x8, pid 1832, pc = f8086308, sr = 2314, stkfmt b, root ptr 931400 Bus Error Reg 0, MMU Status Reg 403 data fault address 38 faultc 0 faultb 0 dfault 1 rw 1 size 1 f0 13 4 0 0 f80ef740 2000 ffffffff There follows a display of A0 thru A7, and a traceback. I'm omitting that for brevity. If anyone would find that helpful in giving _me_ some help, let me know, I'll [post|mail] that out. Does anyone have any idea what this one might be from? As I said, this is the second time it's happened, the first being December 7. Any hints on preventing future recurrences would be GREATLY appreciated! Mitch (@arcturus.uucp)