depner@Thalatta.COM (August Depner) (10/08/90)
I'm having a problem with upgrading from a 3/50 to a 3/60 on our network: the 3/60 reports SCSI bus errors after a few hours and takes the drives offline. If anyone can help, I would greatly appreciate it and I'll summarize the responses. We've been running a 3/50 under 3.5 OS (yeah, I know) for several months as a file server. We have it connected to a Sigma tower containing a CDC Wren IV, a Hitachi DK515C and a cartridge tape drive. No problems. As soon as we upgraded to a 3/60, we received the following errors: /: file system full /: file system full {this goes on for awhile} si 0: Si_cmd: no command phase si 0: resetting scsi bus last phase=0x81 (Arbitration) csr=0x40f bcr=8192 tcr=0x6 cbsr=0x7 (DATA_IN) cdr=0x81 nr=0x0 bsr=0x0 target=1, 1nn=0 DMA addr=0x2000 count=8192 (8192) cdb= a 4 83 d0 10 0 sd0: scsi bus failure si0: sd0, unit offline sda: write retry, blk 15616 (abs blk 15616) sense key (0x6): unit attention, errorcode(0x29):reset panic: hard IO err in swap syncing disks " " " done dumping to dev 701, offset 31948 Exception 0x7c at 0x0F0043F4 {etc....} as the unit fails and reboots sometimes, other times just hangs... We're thinking that the clock speed on the 3/60, being faster than the 3/50, is too fast for the disk. Our SUN FE says our disks are unsupported by SUN, so they can't fix it, though the service manager did offer to look through some bug lists. We're using a fairly standard kernal, though the 3/60 has color instead of monochrome. I'm wondering if anyone out there knows about this problem and if so, can they offer a fix? In-Real-Life: August Depner, Thalatta Corporation, (+1 206 455 9838) Domain: depner@Thalatta.COM Path: ...!sun!sunup!thebes!depner