booter@uunet.uu.net (Elaine M Richards) (02/20/91)
Greetings. I just installed 4.1.1 on my Sparcstation 1+ and have come across a most peculiar problem. uucico appears to scan the Systems file line for the site, skips trying to phone out and goes right to sitting around, picking its little nose and waiting for "login". tip is acting up also. I can "tip cua0", do the ATdt bop and get connected. If I "tip 5551212", the SD light flickers some and it does not dial out. I have tried this on two different modems, a Telebit T2500 which has been in reliable use on another guy's workstation and a Hayes 2400, which I had been using with 4.0.3. I swapped cables, also. Advice? Anyone else get this? I really would like my machine to be able to dial out. I would also like to know if this is a bug of some sort before I go upgrade our two major uucp servers. E. Richards fernwood!autodesk!booter or booter@Autodesk.COM