TELECOM Digest Sat, 12 Aug 89 02:00:33 CDT Special Edition: Wiring Plan
Today's Topics: Moderator: Patrick Townson
Universal Wiring Plan (Richard Tobier)
[Moderator's Note: My thanks to Mr. Tobier for making this information
available to Digest readers. Please note this report contains *Form
Feeds* (^L), and you should adjust your printer/terminal accordingly. PT]
----------------------------------------------------------------------
Date: Thu, 10 Aug 89 11:10:46 EDT
From: Richard Tobier <gould!infocenter!rtobier@uunet.uu.net>
Subject: Universal Wiring Plan
In response to the following:
>From: levitt@zorro9.fidonet.org (Ken Levitt)
>Subject: RS-232 Standards for phone wire
>I would interested in any proposed standards for passing RS-232 over 6
>wire phone connectors. If you or anyone else have this information,
>would you please post it or send it directly to me.
The following are standards that I developed for Encore Computer Corp.
(F.K.A. Gould Inc., Computer Systems Div.). I hope this diagrams are
useful to those on net.
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
Connection Instructions
The attached diagrams should assist in the installation of
terminals to computer ports via the "ENCORE Universal Wiring
Plan".
Materials Necessary:
3 pr. 24 AWG Telephone wire
DB-25 Rs-232 Connectors
6 wire modular telephone line cords, 7 ft, 14 ft, or
25 ft. (One end will be cut off. See diagram for
end to save. Each end is different.)
Punch Tool
Refer to the "Universal Wiring Plan New Installation" Sheet.
Your building has been wired to this specification. Most
outlets where a telephone is present, also has the
capability of supporting an asynchronous terminal. It is
necessary to make cables which connect the terminals to the
telephone jacks, and cables from the Data Backboard to the
Computer Ports.
In cases where there is more than one Computer Room, it may
be necessary to cross connect in the Telco-Room from the
Data Backboard to the appropriate Computer Tie Cable. Cross
Connect all six wires from the data backboard run (cable run
from the Terminal location) to the next available wires (pin
positions) on the Computer Tie Cable Type 66M Block. The
same 'pin positions' in the computer room will be used to
connect the Computer Port Cable.
Refer to the attached sheets for Cable Specifications.
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
Telephone Wire Color Code
QUAD LINE CORD 3-Pair Tip/Ring MOD #
****** ********* ******* ******** *****
---- White Wht/Grn T3 1
BLACK BLACK Wht/Org T2 2
RED RED Blu/Wht R1 3
GREEN GREEN Wht/Blu T1 4
YELLOW YELLOW Org/Wht R2 5
---- BLUE Grn/Wht R3 6
T1 ----------------------O-------------
| } Pair # 1
R1 ------------------O---+-------------
| |
T2 --------------O---+---+-------------
| | | } Pair # 2
R2 --------------+---+---+---O---------
| | | |
T3 ----------O---+---+---+---+---------
| | | | | } Pair # 3
R3 ----------+---+---+---+---+---O-----
| | | | | |
| | | | | |
+-------------------------+
| T3 T2 R1 T1 R2 R3 | <-- Modular Phone Jack
+-------------------------+
+-------------------------+
| 1 2 3 4 5 6 | <-- Modular Phone Plug
+-------------------------+ Pins face up
| |
To Equipment
The above conforms to Jack Wiring for USOC RJ11C 1-pair wiring,
USOC RJ14C 2-pair wiring and USOC RJ25C 3-pair wiring.
LEGEND:
Wht/Blu White wire Blue dot Org/Wht Orange wire White dot
Blu/Wht Blue wire White dot Wht/Grn White wire Green dot
Wht/Org White wire Orange dot Grn/Wht Green wire White dot
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
Telephone Wire Color Code
T1 ----------------------O-------------
| } Pair # 1
R1 ------------------O---+-------------
| |
T2 --------------O---+---+-------------
| | | } Pair # 2
R2 --------------+---+---+---O---------
| | | |
T3 ----------O---+---+---+---+---------
| | | | | } Pair # 3
R3 ----------+---+---+---+---+---O-----
| | | | | |
T4 ------O---+---+---+---+---+---+-----
| | | | | | | } Pair # 4
R4 ------+---+---+---+---+---+---+---O-
| | | | | | | |
| | | | | | | |
+--------------------------------+
| T4 T3 T2 R1 T1 R2 R3 R4 | <-- Modular Phone Jack
+--------------------------------+
+--------------------------------+
| 1 2 3 4 5 6 7 8 | <-- Modular Phone Plug
+--------------------------------+ Pins face up
| |
To Equipment
LEGEND:
Wht/Blu White wire Blue dot Wht/Grn White wire Green dot
Blu/Wht Blue wire White dot Grn/Wht Green wire White dot
Wht/Org White wire Orange dot Wht/Brn White wire Brown dot
Org/Wht Orange wire White dot Brn/Wht Brown wire White dot
Type 66M Telco Block Wire Assignments
PAIR PIN # WIRE COLOR
1 1 WHITE/blue
2 BLUE/white
2 3 WHITE/orange
4 ORANGE/white
3 5 WHITE/green
6 GREEN/white
4 7 WHITE/brown
8 BROWN/white
5 9 WHITE/slate
10 SLATE/white
6 11 RED/blue
12 BLUE/red
7 13 RED/orange
14 ORANGE/red
8 15 RED/green
16 GREEN/red
9 17 RED/brown
18 BROWN/red
10 19 RED/slate
20 SLATE/red
11 21 BLACK/blue
22 BLUE/black
12 23 BLACK/orange
24 ORANGE/black
13 25 BLACK/green
26 GREEN/black
14 27 BLACK/brown
28 BROWN/black
15 29 BLACK/slate
30 SLATE/black
16 31 YELLOW/blue
32 BLUE/yellow
17 33 YELLOW/orange
34 ORANGE/yellow
18 35 YELLOW/green
36 GREEN/yellow
19 37 YELLOW/brown
38 BROWN/yellow
20 39 YELLOW/slate
40 SLATE/yellow
21 41 VIOLET/blue
42 BLUE/violet
22 43 VIOLET/orange
44 ORANGE/violet
23 45 VIOLET/green
46 GREEN/violet
24 47 VIOLET/brown
48 BROWN/violet
25 49 VIOLET/slate
50 SLATE/violet
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
TERMINAL TO COMPUTER PORT
WALL PLUG TERMINAL
RJ11 RS-232 MALE
Modular pins face up
------------ --------------
|6 BLU | (Silver Satin Phone Cord)| BLU |
|5 S/GND YEL |---------/ /-------------| 7 S/GND YEL |
|4 TX GRN |--------/ /--------------| 2 TX GRN |
|3 RX RED | | 3 RX RED |
|2 DTR BLK | | 20 DTR BLK |
|1 WHT | | WHT |
------------ --------------
DATA BACKBOARD TO COMPUTER PORT
66M BLOCK COMPUTER
PUNCH DOWN EIA RS-232
-------------- ---------------
| 1 TX W/b | | 3 TX W/b |
| 2 RX B/w | | 2 RX B/w |
| 3 DTR W/o | ( 3 pr. Phone Cable ) | 4 DTR W/o |
| 4 S/GND O/w |-----------/ /---------| 7 S/GND O/w |
| N/C W/g |----------/ /----------| 4-5-6-8 |
| N/C G/w | | |
-------------- ---------------
|
Tx & Rx crossed in |
this cable. - - - - -+
Legend: W/b White wire with Blue tracer dot
B/w Blue wire with White tracer dot
W/o White wire with Orange tracer dot
O/w Orange wire with White tracer dot
W/g White wire with Green tracer dot
G/w Green wire with White tracer dot
CRT CPU
2 ------------------------ 3
3 ------------------------ 2
7 ------------------------ 7
20 ------------------------ 4 ---+
5 ---+
6 ---+
8 ---+
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
TERMINAL TO COMPUTER PORT
(Hardware Flow)
CRT to RJ45
WALL PLUG CRT
RJ45 RS-232 MALE
Modular pins face up
------------ --------------
|8 CTS SLT | | 5 CTS SLT |
|7 DSR BRN | (Silver Satin Phone Cord)| 6 DSR BRN |
|6 S/GND YEL |---------/ /-------------| 7 S/GND YEL |
|5 TX GRN |--------/ /--------------| 2 TX GRN |
|4 RX RED | | 3 RX RED |
|3 DTR BLK | | 20 DTR BLK |
|2 RTS ORG | | 4 RTS ORG |
|1 BLU | | BLU |
------------ --------------
DATA BACKBOARD TO COMPUTER PORT
66M BLOCK COMPUTER
PUNCH DOWN RS-232 FEMALE
--------------- ----------------
| 1 TX W/bl | | 3 RX W/bl |
| 2 RX Bl/w | | 2 TX Bl/w |
| 3 DTR W/o | ( 4 pr. Phone Cable ) | 5 CTS W/o |
| 4 S/GND O/w |-----------/ /---------| 7 S/GND O/w |
| 5 RTS W/g |----------/ /----------| 6 DSR W/g |
| 6 DSR G/w | | 4 RTS--+ G/w |
| 7 N/C W/br | | | W/Br |
| 8 CTS Br/w | | 20 DTR | Br/w |
--------------- | 8 DCD--+ |
---------------
LEGEND: W/bl White wire with Blue tracer dot
Bl/w Blue wire with White tracer dot
W/o White wire with Orange tracer dot
O/w Orange wire with White tracer dot
W/g White wire with Green tracer dot
G/w Green wire with White tracer dot
W/br White wire with Brown tracer dot
Br/w Brown wire with White tracer dot
CPU CRT
2 ------------------------ 3
3 ------------------------ 2
4 ------------------------ 6
5 ------------------------ 20
+-- 6 ------------------------ 4
| 7 ------------------------ 7
+-- 8
20 ------------------------ 5
ENCORE COMPUTER CORPORATION
Telecommunications Department
Universal Wiring Plan
NEC SPINWRITER CABLE
FOR PRINTER CONNECTION
7700 & 8800
PRINTER UNIX
RS-232 FEMALE 7700 RS-232 FEMALE
RS-232 MALE 8800
2 ------------------------ 3
3 ------------------------ 2
4 ------------------------ 6 -- 8
5 ------------------------ 19
8 -- 6 ------------------------ 4
7 ------------------------ 7
20 ------------------------ 5
Universal Wiring Plan - New Installation
DEFINITIONS:
* Provides Voice and Data capabilities to each location via
Modular Plug and Jack.
* Telco Industry Standard Wire and Connectors.
* Easy Data connections via cross-connects at Data
Backboards.
* Each Data Run numbered same as Voice Run.
REQUIREMENTS:
* Wall Jacks - Duplex 6 Conductor
Top (Right) VOICE - Wire as required by the
phone system
Bottom (Left) DATA - Wired as USOC RJ25C 3-
pair termination
* Two 3-pair Copper station wire to each Universal
Location.
* Air Plenum - Teflon - only as required by local, or
National Electric Code Section 800-3d.
* Voice and Data Wire Run Number to be the same for each
Universal Wire location.
* Wire Run Number to be identified on face of each jack.
* Wire Runs to terminate on 66M type blocks with 89B
Brackets in telco room. Data Backboard to be separate from
Voice Backboard. Data Runs to be numbered on 66M Blocks and
all 6 wires are to be terminated.
Richard Tobier
Telecommunications Analyst
Encore Computer Corp.
6901 W. Sunrise Blvd.
Ft. Lauderdale, FL. 33313
voice (305) 797-5713
fax (305) 797-5666
------------------------------
End of TELECOM Digest Special Edition: Wiring Plan
*****************************