daryl@tcomeng.com (Daryl Jones) (03/23/91)
Tuesday at about 2 pm, several Centrex systems in the 415 area were out of service for about 45 minutes. I received a call back from a Pacific Bell trouble reporting center in North Hollywood after the problem had been corrected. I was told that an error had been made when installing a new translation table in several 5ESS machines. The erroneous change caused all local traffic to be routed to AT&T, instead of handled locally. During the outage, I was able to successfully dial a nearby office. The call sounded very noisy, as if it were going through a very long path. Dial tone was instantaneous. Most calls encountered a weak and distant reorder tone. Are translation table changes implemented in several 5ESS machines all at the same time? I can see how such an error would cause one CO to fail, but would it cause multiple CO's to fail at the same time? Telecommunications Engineering Associates Daryl Jones, KA6VEP 409 Wildwood Drive So. San Francisco, CA 94080 Phone: (415) 871-4200 {decwrl,pacbell}!tcomeng!daryl