sysprga@sahiways.gov.au (Trevor Bate) (03/14/89)
HELP! Is anyone using Emulex Performance 4000 terminal servers? We have two and they work perfectly well as long as we don't want to connect to a PDP 11/44 running RSX-11M Plus V3.0. Has anyone else experienced these, or other problems with these terminal servers? The P4000 seems to recoginize the PDP, shows it as a valid service, but gives an error when you attempt to connect to it. Trevor Bate, Highways Department, South Australia. (08) 343 2021 BATE@sahiways.gov.au
system@vaxa.uwa.oz (Systems Programmer, VAXA) (04/17/89)
In article <486@sahiways.gov.au>, sysprga@sahiways.gov.au (Trevor Bate) writes: > HELP! Is anyone using Emulex Performance 4000 terminal servers? > > We have two and they work perfectly well as long as we don't want > to connect to a PDP 11/44 running RSX-11M Plus V3.0. Has anyone > else experienced these, or other problems with these terminal > servers? > > The P4000 seems to recoginize the PDP, shows it as a valid service, but > gives an error when you attempt to connect to it. > IF you have 1.02 of the server image, you turn on 'EMULEX option 1' ( disable LAT packet checking) and it all workes... We have been testing them at WA Dept of Agriculture for a month or so. So far, so good. Paul Repacholi (09) 368 3438