[comp.sys.dec] VAX 11/730 R80 Problems

jar@konkord.uucp (John Roberts) (09/26/90)

	Here's my Vax question for today,

	We have a 730 at school with a R80 drive. When we tried to
	load VMS on it, Standalone backup would come back with
	'FATAL CONTROLLER ERROR!'. So, being a smart person, I went
	out and found the first R80/RL02 (there on the same board)
	I could find. I put the new controller in the 730 and was
	ready for it to load vms. No such luck. Same problem. I then
	checked all the cables going to and from the R80, (yes, I
	'ohmed' each 50+ pin cable. What else is there to do at school?)

	Nothing wrong with the cables. I then got my hands on a R80
	diag book from DEC. I ran ALL the tests on the R80 (the R80
	has self diags like the RA series). ALL the tests passes.

	I then tried to load VMS on RL02 (yes, I know, RL02 are only 10meg)
	But it did load VMS (for the first 10 meg at least).

	So, as you can imagine, I am very confused. WHAT COULD BE THE
	PROBLEM????

	Any help would be great! Thank!!!!



-- 
John A. Roberts				(508)460-4646 X197
Concord Communications, Inc.			uunet!konkord!jar
753 Forest Street					or
Marlboro, MA 01752, USA				jar%konkord@uunet.uu.net

terry@spcvxb.spc.edu (Terry Kennedy, Operations Mgr) (09/28/90)

In article <1990Sep25.212602.5815@uunet!konkord>, jar@konkord.uucp (John Roberts) writes:
> 	So, as you can imagine, I am very confused. WHAT COULD BE THE
> 	PROBLEM????

  Two things come to mind: 1) The personality module on the R80 could be
bad - the tests don't check all of it, or 2) You have found a stand-alone
backup bug (welcome to the [large] club). Try an older or newer version
and see if that helps.