zaft@suned1.nswses.navy.mil (Gordon C Zaft) (04/24/91)
I've been experiencing a number of soft errors on a Wren VI ESDI
disk drive in my MicroVAX II under VMS 5.4-1. I've tried reformatting the
drive to no avail. Anyone have any ideas what might be causing the
problem? The controller is an Emulex QD-21.
TIA
Error log entry follows
------------------------------------------------------------------------------
B E G I N I N G O F I N T E R V E N I N G E N T R I E S
V A X / V M S SYSTEM ERROR REPORT COMPILED 23-APR-1991 10:52:58
PAGE 7.
******************************* ENTRY 7. *******************************
ERROR SEQUENCE 12683. LOGGED ON: SID 08000000
DATE/TIME 1-APR-1991 11:53:56.37 SYS_TYPE 01010000
SYSTEM UPTIME: 1 DAYS 23:44:59
SCS NODE: VAX/VMS V5.4-1
ERL$LOGMESSAGE ENTRY KA630
I/O SUB-SYSTEM, UNIT _DUB0:
MESSAGE TYPE 0001
DISK MSCP MESSAGE
MSLG$L_CMD_REF 74610012
MSLG$W_UNIT 0000
UNIT #0.
MSLG$W_SEQ_NUM 0002
SEQUENCE #2.
MSLG$B_FORMAT 02
DISK TRANSFER ERROR
MSLG$B_FLAGS 40
OPERATION CONTINUING
MSLG$W_EVENT 0068
DATA ERROR
DATA SYNC NOT FOUND
MSLG$Q_CNT_ID 31000200
01060000
UNIQUE IDENTIFIER, 000031000200(X)
MASS STORAGE CONTROLLER
UDA50A
MSLG$B_CNT_SVR D5
CONTROLLER SOFTWARE VERSION #213.
MSLG$B_CNT_HVR 04
CONTROLLER HARDWARE REVISION #4.
MSLG$W_MULT_UNT 6C00
MSLG$Q_UNIT_ID 02000200
02050000
UNIQUE IDENTIFIER, 000002000200(X)
DISK CLASS DEVICE (166)
RA81
MSLG$B_UNIT_SVR 00
UNIT SOFTWARE VERSION #0.
MSLG$B_UNIT_HVR 00
UNIT HARDWARE REVISION #0.
MSLG$B_LEVEL 00
MSLG$B_RETRY 01
MSLG$L_VOL_SER 00008E09
VOLUME SERIAL #36361.
MSLG$L_HDR_CODE 00052C40
LOGICAL BLOCK #339008.
GOOD LOGICAL SECTOR
--
+ Gordon Zaft | zaft@suned1.nswses.navy.mil +
+ NSWSES, Code 4Y33 | suned1!zaft@elroy.jpl.nasa.gov +
+ Port Hueneme, CA 93043-5007 | Phone: (805) 982-0684 FAX: 982-8768 +
** ..et resurrexit tertia die secundum scripturas, et ascendit in coelum.. ***