[comp.unix.xenix] Problem with Irwin streamer under SCO UNIX.

dp@adagio.chorus.fr (Didier Poirot) (11/30/89)

   	I would like to know if someone has already experienced problems with
Irwin mini-streamer on Compaq386, running SCO UNIX System V.

	I succeed in formatting and writing ~35000 blocks, as stated below:

# tape servo
# tape format
# find / -print| cpio -ov -O/dev/rctmini
...
...
...
...
...
33512 blocks
#

	The problem appeared when I try to read the cartridge. After some
files are read, cpio complains with:

# cpio -vit -I/dev/rctmini
...
...
...
last file displayed
I/O error on read().
#

	The problem always occurs after the same file (many tries). First,
I thought it was a tape problem, and then I  tried with another tape. Same
results, cpio refused to read after a certain file, always the same on a given
tape.

 I tried with the differents options of SCO cpio. Same results.

	Sometimes, when the tape is nearly full, cpio -ivt -I/dev/rctmini
blocks, no messages , and I have to reboot the system , or to power  it down
to  regain access to the streamer. The cpio process is un-killable.
CTL-ALT-DEL is ineffective.

Configuration:

Compaq386/25 with 6 Mbytes, 1 5"1/4 floppy disk, 1 type 33 disk,1 Irwin
mini-streamer.

SCO UNIX System V release 3.2.0 system
kernel id 1.91 with Maint. Sup. A

The streamer driver had been linked in the kernel with sysadmsh facility
(System->Hardware->Tape) Unit number: 4


	Hope someone can help me.


          /     /               Didier Poirot
       __/ o __/ o _  __        Chorus Systemes
      (_(_(_(_(_(_(<_/ (_       6 avenue Gustave Eiffel
                                F-78182, St-Quentin-en-Yvelines-Cedex

dp@chorus.fr (Internet)         mcvax!inria!chorus!dp (uucp)