[comp.periphs] DEC RM05's on Alliant FX/8 Xylogics

hr@uicsl.csl.uiuc.edu (03/31/88)

RE:
> Does anybody have any information on how to hook up DEC RM05's
> to an Alliant FX/8 with a Xylogics 451 controller?

Someone mentioned in SunSpots that DEC's version of the 9766 was
modified so it probably wouldn't work with the 451. On the other
and, I have a System Industries 9766 hooked up to a 451 on a Sun.
Mine is set up for 823 cylinders (counting 2 as spare), 19 heads,
32 sectors/track (counting 1 for sliping), and 630 bytes/sector
(counting overhead).
I think 33 sectors/track would give a runt that is too small for
the 451 to deal with.

What I haven't been able to figure out is why my Super Eagle won't
work with the 9766. I finally just moved it to another system.

Here is a little table I drew up that helped me:
-----------------
.\" tbl | (p)troff -me
.po 1.0i
.ll 6.5i
.ps +3
.ft B
.ce
Comparison of Fujitsu 2361A, CDC 9766, and XYLOGICS 451 A cable pinouts
.ce
\n(mo/\n(dy/\n(yr
.ft R
.ps -3
.sp 2
.TS
center allbox;
c c c c c
c l l l c.
CDC	Function	Function	Function	Xylogics
#s	Fujitsu	2361	CDC	Xylogics	#s

1/31	Tag1	Tag 1	Tag 1 (Cylinder Select)	1/2
2/32	Tag2	Tag 2	Tag 2 (Head Select)	3/4
3/33	Tag3	Tag 3	Tag 3 (Control)	5/6
4/34	Bus 0	Bit 0	Bus Bit 0	7/8
5/35	Bus 1	Bit 1	Bus Bit 1	9/10
6/36	Bus 2	Bit 2	Bus Bit 2 *	11/12
7/37	Bus 3	Bit 3	Bus Bit 3 *	13/14
8/38	Bus 4	Bit 4	Bus Bit 4	15/16
9/39	Bus 5	Bit 5	Bus Bit 5	17/18
10/40	Bus 6	Bit 6	Bus Bit 6	19/20
11/41	Bus 7	Bit 7	Bus Bit 7 *	21/22
12/42	Bus 8	Bit 8	Bus Bit 8 *	23/24
13/43	Bus 9	Bit 9	Bus Bit 9	25/26
14/44	Open Cable Detect	Open Cable Detect	Open Cable Detect	27/28
15/45	Status 3	Fault	Fault	29/30
16/46	Status 2	Seek Error	Seek Error	31/32
17/47	Status 1	On Cylinder	On Cylinder	33/34
18/48	Status 6	Index	Index Pulses	35/36
19/49	Status 0	Unit Ready	Unit Ready	37/38
20/50	Status 5	Adrs Mrk	Adrs Mark *	39/40
21/51	Busy (Dual Channel)	Busy	Busy	41/42
22/52	Unit Select Tag	Unit Select Tag	Unit Select Tag	43/44
23/53	Unit Select 1	Unit Select 2^0	Unit Select Bit 0	45/46
24/54	Unit Select 2	Unit Select 2^1	Unit Select Bit 1	47/48
25/55	Status 7	Sector	Sector Pulses	49/50
26/56	Unit Select 4	Unit Select 2^2	Unit Select Bit 2	51/52
27/57	Tag 5 (selectable)	Unit Select 2^3	Unit Select Bit 3	53/54
28/58	Status 4	Write Protected	Write Protected	55/56
29/59	Pick/Hold	Pick/Hold	Pick/Hold always on	57/58
30/60	Tag 4	NC	Bus Bit 10	59/60
.TE
.sp
.np
Items with star (*) are not used on Xylogics ctlr
(For Bus bits, this probably means alternate functions not listed here.)
.np
A cable termination: 56 ohms to ground. (+/- 10%, 1/10W).
.np
The 2361A uses TAGs 4 & 5 to access different status functions on Status
lines 0..7. (Unit Status, Sector Status, Write/Read Check Status and Access
Status).
-----------------

Harold Ravlin
hr@spica.astro.uiuc.edu
----

	harold ravlin		{ihnp4,pur-ee}!uiucuxc!pollux!hr
				  (hr@pollux.astro.uiuc.edu)?