[comp.periphs] Adaptec 4520A questions/problems

meulenbr@cstw68.prl.philips.nl (Frans Meulenbroeks) (06/28/90)

Hi,

While hooking up my hard disk (Micropolis 1355) to my controller
(Adaptec 4520A), I stumbled upon a few problems and questions.
If anyone can help me with any of these, this would be appreciated
greatly.

The problems are:
1 mode select does not allow me to specify a cylinder skew of 1.
  However, according to the manual this should be possible.
  The only value I could use was 0 (the controller and drive
  operate in hard sectored mode). How come? Is this a bug in 
  the controller??
  Other values result in an illegal parameter error (code 0x26)
2 When reading a number of sectors, which span a cylinder boundary
  sometimes the read command fails.
  request sense returns error code 2 (no seek complete) with sense key
  3 (medium error). However the user manual says that error code 2
  should be accompanied with sense key 4 (hardware error).
  Why this difference?
3 Why do I get the no seek complete when reading across a cylinder
  boundary? Does this have to do with the fact that the controller
  will disconnect across cylinder boundaries??
4 What does no seek complete actually mean.
  The user manual just says "seek complete signal missing"
  which does not help very much either, since I could not find 
  a signal labelled seek complete on any of the connectors.

I've figured out that it is very unlikely that it is a temperature or
power problem.
Since I've spent already quite some time on this problem, even the
tiniest suggestion is very welcome. 

Many thanks,
Frans Meulenbroeks        (meulenbr@cst.philips.nl)
	Centre for Software Technology
	( or try: ...!mcsun!phigate!prle!cst!meulenbr)