[comp.dcom.modems] Using Telebit TB+'s under AOS/VS.

tomwest@gpu.utcs.toronto.edu (Tom West) (03/29/88)

  Has anyone tried using Telebit Trailblazer+'s with Data General Machines
under AOS/VS?  We have managed to do reasonably well with the following
register changes:

	S45=255 (Remote Enable)
	S51=5	(19.2k)
	S52=2	(Drop line on no DTR)
	S53=2	(DCD & DSR interpretation)
	S54=1	(Pass break signals)
	S58=0	(No flow control)
	S66=1	(lock interface)

  On the terminal TB+, we have
	S51=255	(Autospeed)
	s66=1	(Lock interface)
	S110=1	(Compress)
	S111=0  (No kermit)

  Unfortunately, there seems to be some difficulty getting the TB's
to respond to ctrl-C ctrl-A (AOS/VS's break signal) and immediately.
It tends to require some repetition.  Anybody have some way of getting
better response to this?

  (We have Firmware 4.00 on all the TB+'s.)

-- 
				Tom West

BITNET:         tomwest@utorgpu.bitnet, tomwest@gpu.utcs.utoronto
Internet:       tomwest@gpu.utcs.toronto.edu 
UUCP:           tomwest@utgpu 

		utzoo, yetti, harpo, mnetor \
		cbosgd, deepthot, utoronto  -  !utgpu!tomwest
		ihnp4, lsuc, sfmin, vnr-vpa /