[comp.dcom.modems] lightning on the phone lines

zeeff@b-tech.UUCP (Jon Zeeff) (10/05/88)

Having lost 3 modems in two lightning storms, I am suddenly interested 
in surge suppressors for the phone lines.  I bought an inexpensive one 
that appears to have a small glass tube running from each line to 
ground.  The tubes look like large diodes, except that inside they 
appear to have something like a resistor inside.  I beefed this up by 
adding MOVs from each line to ground.  

Is this adequate protection?

The modems were turned off when they were ruined - is it better to leave
them on?

-- 
Jon Zeeff      			Branch Technology,
umix!b-tech!zeeff  		zeeff@b-tech.ann-arbor.mi.us

tr@wind.bellcore.com (tom reingold) (10/06/88)

Check out this month's Byte magazine.  There's an article on this
topic (not specific to modems).  They point out that surge suppressors
are not usually all that helpful.  According to the article, you
have to spend at least $250 to get something assuring and worthwhile.

You obviously know more about circuits than I do, so your addition
of MOVs to your suppressor could be adequate.  I have no idea.

Read the article rather than taking my understand of their conclusions
seriously.

Tom Reingold
PAPERNET:                      |INTERNET:       tr@bellcore.bellcore.com
Bell Communications Research   |UUCP-NET:       bellcore!tr
445 South St room 2L350        |SOUNDNET:       (201) 829-4622 [work],
Morristown, NJ 07960-1910      |                (201) 287-2345 [home]

henry@utzoo.uucp (Henry Spencer) (10/07/88)

In article <4789@b-tech.UUCP> zeeff@b-tech.UUCP (Jon Zeeff) writes:
>Having lost 3 modems in two lightning storms, I am suddenly interested 
>in surge suppressors for the phone lines.  I bought an inexpensive one 
>that appears to have a small glass tube running from each line to 
>ground.  The tubes look like large diodes, except that inside they 
>appear to have something like a resistor inside.  I beefed this up by 
>adding MOVs from each line to ground.  

This isn't necessarily a good idea.  Protecting phone lines is much
trickier than protecting power, because phone lines have to meet fairly
strict electrical specs or you will have trouble, either equipment failure
or nasty mail from the phone company.  For example, I trust your MOVs
are rated for a nice high voltage (ringing voltages are *not* low) and
have quite low leakage currents at normal voltages (so the phone company
doesn't conclude that there's an equipment fault somewhere)?  I would
not recommend adding components yourself unless you have checked specs
carefully and know what you're doing.
-- 
The meek can have the Earth;    |    Henry Spencer at U of Toronto Zoology
the rest of us have other plans.|uunet!attcan!utzoo!henry henry@zoo.toronto.edu

berger@clio.las.uiuc.edu (10/08/88)

If the glass tubes are gas discharge tubes, they're pretty good
protection, PROVIDED you have a good ground.