[comp.dcom.modems] TB+ Reset time

eric@sactoh0.UUCP (Eric J. Nihill) (09/12/89)

I am trying to find a way to increase the reset speed of
my TB+. I currently search 2400,1200,PEP. If a call 
comes in at 2400 and then disconnects, the TB+ will
answer any call that come in within the next 60 (aprox)
seconds in PEP. It seems to take the S92 register that
long to get recognized and reset. 
I need to get a faster reset due to the fact that the 
modems get high incoming use. (80% busy,2-6 hits per hour).
Other registers:
S7=40 S10=7 S47=4 S52=2 S53=4 S92=1
                     Thank-you;
                              Eric
-- 
When in trouble, worry or doubt,            sactoh0!eric   
run in circles, scream and shout.         Flick (Fletch?) Lives