[comp.dcom.modems] uucp and the Telebit T2500

brian@fog.ann-arbor.mi.us (Brian S. Schang) (09/26/90)

I am having minor problems getting my Telebit T2500 to work properly
with uucp.  When I dial out and get a busy signal, I get the following
in my LOGFILE:

uucp ***** (9/25-21:38-676) FAILED (BUSY)
uucp ***** (9/25-21:38-676) LOST LINE (LOGIN)
uucp ***** (9/25-21:38-676) HSM did not respond to ATZ (modem)
uucp ***** (9/25-21:38-676) FAILED (call to umich )

When I use my Hayes 2400 I get only the following:

uucp ***** (9/25-21:38-676) FAILED (BUSY)
uucp ***** (9/25-21:38-676) FAILED (call to umich )

I'm not sure why.  It's a minor problem, and works OK the way it is, but my
curiousity is intrigued.  I don't understand why I get the extra two entries. 
My T2500 settings are as follows:

E1 F1 M0 Q4 T V1 W0 X14 Y0 &P0 &T4     Version GE6.01-T2500
S00:000 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006
S10=007 S11=070 S12=050 S18=000 S25=005 S26=000 S38=000
S41=000 S45=000 S47=004 S48=000 S49=000
S50=000 S51:005 S52:002 S54:003 S55=000 S56=017 S57=019 S58:000 S59=000
S61=150 S62=003 S63=001 S64=000 S65=000 S66:001 S67=000 S68=255 S69=000
S90=000 S91=000 S92=000 S93=008 S94=001 S95:002 S96:000 S97=000 S98=003
S100=000 S101=000 S102=000 S104=000 S105=001 S106=000 S107=020
S110:000 S111:030 S112=001
S121=000 S130=002 S131:003
S150=000 S151=004 S152=001 S153=001 S154=000 S155=000
S160=010 S161=020 S162=002 S163=003 S164=007 S255=000

Can anyone see any setting errors in regards to the aforementioned problem or
any setting errors in general?  I'm using A/UX 1.1 and my understanding
is that I cannot use flow control do to lack of appropriate lines.  I dial
into a Trailblazer and use PEP.

Any insight would be appreciated.  Thanks!
-- 
Brian S. Schang   N8FOG          brian@fog.ann-arbor.mi.us
46131 Academy Drive              schang@caen.engin.umich.edu