dag@fciva.FRANKLIN.COM (Daniel A. Graifer) (01/16/91)
We have several Telebit Trailblazer Plus modems and one T2500 (v7.00) modem on various machines. In uucp mode (S111=30) at 19200bps I can easily call between the TB+s and from the T2500 to them. When I try to call from the TB+s to the T2500, the modems never finish handshaking, the T2500 repeats the last part of the sequence (short-short-LONG-pause(2) whitenoise(3) pause over and over). I've set up S7 to 60 so the calling modem doesn't time out, and added "\r\d\d\d\d\c" to the Dialer sequence so uucico doesn't timeout waiting for the connect. Oh, I have the register set to present PEP at the end (S92=1). Anybody have any ideas? How about a tech support number at Telebit? Thanks in advance. Dan -- Daniel A. Graifer Coastal Capital Funding Corp. Sr. Vice President, Financial Systems 7900 Westpark Dr. Suite A-130 (703)821-3244 McLean, VA 22102 uunet!fciva!dag fciva.FRANKCAP.COM!dag@uunet.uu.net
cec@cup.portal.com (Cerafin E Castillo) (01/18/91)
Try setting S92=0 (PEP, V.25...) and see if anything changes. If not, there may be a problem with the calling modem hearing the answering modem. There is a problem with the automatic gain control (AGC) in earlier revisions of modem firmware. I have seen various net users post their experiences with this problem to this group. If this is the problem, then the calling modem is not hearing the answering modems tones. Telebit Tech Support is best at dealing with this. You can reach them at 1-800-TELEBIT. Good Luck! =============================================================================== Cerafin E. Castillo || //\\ ||\\ || Network Consultant || //__\\ || \\ || Los Altos Los Altos Networks || // ---\\|| \\|| Networks 340 Second St. #6 ||___// \ | \ | Los Altos, CA 94022 (415) 941-8031 UUCP: {apple,sun,uunet}!portal!cup.portal.com!cec INTERNET: cec@cup.portal.com "...No hay mal que por bien no venga..." ===============================================================================
dag@fciva.FRANKCAP.COM (Daniel A. Graifer) (01/20/91)
In article <38156@cup.portal.com> cec@cup.portal.com (Cerafin E Castillo) writes: >Try setting S92=0 (PEP, V.25...) and see if anything changes. If not, >there may be a problem with the calling modem hearing the answering >modem. There is a problem with the automatic gain control (AGC) in >earlier revisions of modem firmware. I have seen various net users >post their experiences with this problem to this group. If this is >the problem, then the calling modem is not hearing the answering modems >tones. Telebit Tech Support is best at dealing with this. You can >reach them at 1-800-TELEBIT. Good Luck! > >Cerafin E. Castillo Well I tried setting S92=0, and started connecting. Very Strange! So I called Telebit Tech Support as suggested. Telebit had me try setting the undocumented register S120=16. I asked him what this register did, and he said something about V.25 and echo suppression. Anyways, it works. I can now connect in PEP mode between my TB+ and my T2500 with the latter trying PEP tones last. Anyways, many thanks to Cerafin, (and of course to Telebit!). Dan -- Daniel A. Graifer Coastal Capital Funding Corp. Sr. Vice President, Financial Systems 7900 Westpark Dr. Suite A-130 (703)821-3244 McLean, VA 22102 uunet!fciva!dag fciva.FRANKCAP.COM!dag@uunet.uu.net