oli@odbffm.incom.de (Oliver Boehmer) (05/11/91)
Hi! I'm trying to establish a transatlantic connection with a Trailblazer T1600 in V32 mode with error correction (V42 or MNP) Up until now, all we've been able to get was a CONNECT 2400, nothing else. Could someone please mail me his register-settings and/or correct ours. Help would be appreciated, tx, oli Settings T1600 Same as factory setting &F3, changes as follows: S111=0 S104=3 S180=2 S7=100 S181=2 S50=6 And the T2500: (only the ones different from factory default) S50=6 S90=1 S95=2 S97=1 S106=1 What else do we have to do? Hope, somebody can help me.... -- Oliver Boehmer, Frankfurt, Germany oli@odbffm.incom.de +49-69-331461 (voice) +49-69-308265 (1200/2400) If God is perfect, why did He create discontinuous functions?
davidg%aegis.or.jp@kyoto-u.ac.jp (Dave McLane) (05/12/91)
oli@odbffm.incom.de (Oliver Boehmer) writes: > Hi! > I'm trying to establish a transatlantic connection with a Trailblazer T1600 > in V32 mode with error correction (V42 or MNP) > Up until now, all we've been able to get was a CONNECT 2400, nothing else. > Could someone please mail me his register-settings and/or correct ours. > Help would be appreciated, tx, oli I'm running a T2500 on my system and access it with a T1600. Here are the dialout settings for the (U.S. model) T2500: E0 F1 M1 Q9 P V1 W1 X3 Y0 &P0 &T4 Version GE6.01-T2500 S00=001 S01=000 S02:128 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006 S10=007 S11:050 S12=050 S18=000 S25=005 S26=000 S38:255 S41=000 S45=000 S47=004 S48=000 S49=000 S50=000 S51:254 S52:002 S54=000 S55=000 S56=017 S57=019 S58:002 S59=000 S61:001 S62=003 S63=001 S64=000 S65=000 S66:002 S67=000 S68=255 S69=000 S90:001 S91=000 S92=000 S93=008 S94=001 S95:002 S96=001 S97:001 S98=003 S100=000 S101=000 S102=000 S104=000 S105=001 S106:001 S107=020 S110=255 S111=255 S112=001 S121=000 S130=002 S131:001 S150=000 S151=004 S152=001 S153=001 S154=000 S155=000 S160=010 S161=020 S162=002 S163=003 S164=007 S255=000 N0:\IRA N1:\ I add the following to dialout to connect (only) in PEP mode to another T2500 (never dialout to connect to anything else): ATS50=255S111=30 ------------------------------ Here are the dialin settings for the (U.S. model) T1600: T1600 - Version LA1.00 - Active Configuration B1 E1 L1 M1 P Q0 V1 X2 Y0 &C1 &D3 &G0 &J0 &L0 &Q0 &R3 &S3 &T4 &X0 S000=0 S001=0 S002:128 S003=13 S004=10 S005=8 S006=2 S007=40 S008=2 S009=6 S010=14 S011:50 S012=50 S018=0 S025=5 S026=1 S038:255 S041=0 S045=0 S046=0 S047=4 S048=0 S050=0 S051:253 S056=17 S057=19 S058:2 S059:1 S060=0 S061=1 S062=15 S063=0 S064=0 S068=255 S069=0 S090=0 S093=8 S094=1 S100=0 S102=0 S104=0 S105=1 S111=255 S112=1 S180=2 S181:0 S183=25 S190=1 S253=10 S254=255 S255=255 ------------------------------ Here are the dialout settings for the (U.S. model) T1600: T1600 - Version LA1.00 - Active Configuration B1 E1 L1 M1 P Q0 V1 X2 Y0 &C1 &D3 &G0 &J0 &L0 &Q0 &R3 &S0 &T4 &X0 S000=0 S001=0 S002=43 S003=13 S004=10 S005=8 S006=2 S007=40 S008=2 S009=6 S010=14 S011:50 S012=50 S018=0 S025=5 S026=1 S038=0 S041=0 S045=0 S046=0 S047=4 S048=0 S050=0 S051=255 S056=17 S057=19 S058:2 S059:15 S060=0 S061=1 S062=15 S063=0 S064=0 S068=255 S069=0 S090=0 S093=8 S094=1 S100=0 S102=0 S104=0 S105=1 S111=255 S112=1 S180=2 S181=1 S183=25 S190=1 S253=10 S254=255 S255=255 180=2 S181=1 S183=25 S190=1 S253=10 S254=255 S255=255 ------------------------------ Hope that helps, --Dave -- Dave McLane <davidg%aegis.or.jp> JUNET <davidg%aegis.or.kyoto-u.ac.jp> INTERNET <davidg%aegis.or.jp@jpnkyoto.kyoto-u.ac.jp> BITNET <davidg%aegis.or.jp%kyoto-u.ac.jp@uunet.uu.net> UUNET ==== The Aegis Society ============================================= Minami Hirao 1-6, Imazato The content and process of Nagaokakyo-shi, Kyoto-fu, 617 Japan international/cultural Tel: +81-75-951-1168 Fax: +81-75-957-1087 communication. ==================================================================== -- Dave McLane <davidg%aegis.or.jp@kyoto-u.ac.jp>
gandrews@netcom.COM (Greg Andrews) (05/13/91)
In article <1991May10.201244.21752@odbffm.incom.de> oli@odbffm.incom.de (Oliver Boehmer) writes: >Hi! >I'm trying to establish a transatlantic connection with a Trailblazer T1600 >in V32 mode with error correction (V42 or MNP) >Up until now, all we've been able to get was a CONNECT 2400, nothing else. >Could someone please mail me his register-settings and/or correct ours. >Help would be appreciated, tx, oli > >-- >Oliver Boehmer, Frankfurt, Germany oli@odbffm.incom.de > Which modem is answering and which is originating? The answering modem may need to lengthen its AC tone length. In the T2500 this is controlled by the S93 register. I don't have the T1600 manual with me at the moment, so I don't know if there's a comparable register. If the modem in Frankfurt is answering the call, your friend in the USA could call Telebit support and have them try to make a connection... -- .------------------------------------------------------------------------. | Greg Andrews | UUCP: {apple,amdahl,claris}!netcom!gandrews | | | Internet: gandrews@netcom.COM | `------------------------------------------------------------------------'