[comp.dcom.modems] over 1000cps

cwright@pain.UUCP (Chris Wright) (06/25/91)

You should be able to go to about 1024 cps with those two Telebit 
modems...the only time I have seen the kind of errors you have described 
is when someone attempts to upload a file to a bbs that is running a 
locked com port at 38.4k and the bbs program is running under multi 
tasking software with other task running....of course the way to correct 
that is to replace the UART chip with a 16550 UART chip, this chip will 
enable high speed transfer to work reliably under DEssqview and other 
programs....
                        Chris Wright
                celia!techsys!pain!cwright

--
                         celia!techsys!pain!cwright
              Public Access Information Network  (818/776-1447)
                            ++ Waffle BBS v1.64 ++

li@mrcnext.cso.uiuc.edu (hans li) (06/25/91)

The other way to avoid errors under multitasking is to lock the port 
at 19.2 instead of 38.4