[net.periphs] Emulex TC7000 update

stevens@hsi.UUCP (Richard Stevens) (08/22/85)

Emulex was able to duplicate the problem we encountered with the TC7000,
under VMS, so they found the problem and fixed it.  (The problem is that on
a read of certain record lengths, the controller will return the correct
length but will NOT transfer all of the data into your buffer.  If you
didn't know what you were reading (or if the data didn't contain a software
checksum) you never knew you were missing data!!)

They sent us a new set of PROMs (level HX1) to beta test, which I assume
will become the standard level I PROMs.  Since most TC7000s are level G
or H, you will probably want to contact Emulex to get a new set of PROMs,
ASAP.  The contact in their Tech Support Group for this problem is Wade
Woolridge.

	Richard Stevens
	Health Systems International, New Haven, CT
           ihnp4 ! hsi ! stevens