[sci.electronics] Latching Relays

atn@cory.Berkeley.EDU (Alan Nishioka) (09/21/89)

For a friend's mechanical engineering project I needed a circuit that
latched.  I built a circuit using two SPDT relays in which power through
one coil closed a switch which energized the second coil which closed a
switch which energized the first coil, or something like that :-)  Kinda
like an RS latch.  This worked fine for my application, except there was
a condition where if the wrong switch was closed, the system would
oscillate.

Does a simple device exist which does this sort of thing?  (ie. Is there
a better way to build a circuit with memory?  (perhaps with transistors))
I didn't want to use a 7474 for simplicity and power supply reasons.
 
At the time, I looked at some of the "latching relays" I had heard about.
These apparently have two coils, and a pulse to one coil latches the 
switch one way, while a pulse to the other coil latches the switch in the
other state.  This wouldn't have been useful to my application.

Alan Nishioka            atn@cory.berkeley.edu            ...!ucbvax!atn%cory

erk@americ.UUCP (Erick Parsons) (09/22/89)

From: atn@cory.Berkeley.EDU (Alan Nishioka) Message-ID: <17419@pasteur.Berkeley.EDU>

>For a friend's mechanical engineering project I needed a circuit that
>latched.  I built a circuit using two SPDT relays in which power through
>one coil closed a switch which energized the second coil which closed a
>switch which energized the first coil, or something like that :-)  Kinda
>like an RS latch.  This worked fine for my application, except there was
>a condition where if the wrong switch was closed, the system would
>oscillate.

A very common latching circuit (for motor control) is to use one
relay with two sets of contacts. It is a DPDT relay.         ^^^

It requires three wires in the control conduit, two switches: SPST
momentary contact, one normally open and one normally closed.

                    1st set of contacts
                        for control
                         _________                               Hot
                        |         |                        ___    |
          ------o-----------|/|-----------o-------------- .   . --o
          |             |         |                               |
          o-----o-----------| |-----------o-------------- .---. --o
          |             |_________|
          |
          |                  C
          |-----o------------O------------o-----------------------o
                             I                                    |
                             L                                   Gnd
                         _________
                        |         |
                o-----------|/|-----------o
                        |         |
                o-----------| |-----------o
                        |_________|

                    2nd set of contacts
                         for load

-----------symbols used------------

|/| normally closed  contact of relay

| | normally open    contact of relay

.---. normally closed  momentarily opened manually operated switch
 ___
.   . normally open    momentarily closed manually operated switch


--
 -------------------  // ----------------------------------------------------
  Erick Parsons      //  Knowledge is little more than  knowing the questions
  -------------     //   erk@americ.UUCP or ..ames!pacbell!sactoh0!americ!erk
  Sacramento Ca \\ //    GEnie: E.PARSONS      %-)       Hamatuer Radio N6RZB
 --------------  \X/ --------------------------------------------------------

larry@kitty.UUCP (Larry Lippman) (09/24/89)

In article <2030.AA2030@americ>, erk@americ.UUCP (Erick Parsons) writes:
> A very common latching circuit (for motor control) is to use one
> relay with two sets of contacts. It is a DPDT relay.         ^^^
> It requires three wires in the control conduit, two switches: SPST
> momentary contact, one normally open and one normally closed.
>                          _________                               Hot
>                         |         |                        ___    |
>           ------o-----------|/|-----------o-------------- .   . --o
>           |             |         |                               |
>           o-----o-----------| |-----------o-------------- .---. --o
>           |             |_________|
>           |
>           |                  C
>           |-----o------------O------------o-----------------------o
>                              I                                    |
>                              L                                   Gnd
>                     2nd set of contacts
>                          for load

	The above scheme is inadvisable, and simply will not work with
many relays.  The reason is that most relays intended for power control
purposes have a SPDT contact configuration known as "break-make" (BM).
Operating the NO "on" switch will energize the coil, but as the armature
begins to pull in, the break contact will break, interrupting the current
flow to the coil BEFORE the make contact will make to latch the relay on.
The net result is that the relay will chatter, but never pull in to a
fully operated and latched state.

	While a contact configuration of "make-break" (MB) will permit the
above circuit to be functional, such a MB contact arrangement is relatively
uncommon in a power control relay.  In reality, running the "on" switch
with a break relay contact serves no useful purpose.  The above circuit may
be used if the "on" switch is connected directly to the relay coil, with
the break contact being unused.  A motor contactor, for example, uses a
single make contact for the latch circuit.

	While the heyday of relay logic control circuits has now passed
due to the advent of solid-state logic, microprocessors, and industrial
Programmable Logic Controllers (PLC's), relay contact timing can still be
a problem if not considered in the design of some control circuits.

	The concept of relay and relay contact timing was honed to a fine
art in the days when telephone switching circuits were solely designed
using electromechanical technology.  As an example, a common style of
of wire-spring telephone relay having TWELVE contact sets could be
configured with any combination of make (M), break (B), make-break (MB),
break-make (BM), early make-break (EMB), early break-make (EBM), early
make (EM) and early breek (EB) contacts!  In addition, not only could
such a relay be designed with up to three separate windings, but it
could be designed using copper slugs as an additional one-turn winding
to effect either a "slow-release" or "slow-operate" relay with effective
"slow" timing as great as 250 milliseconds.

	I'd like to make one other point as long as I am here on my
soapbox. :-)  I do not fault the above poster for his circuit suggestion,
even though it is generally unworkable.  At first glance, the circuit
seems reasonable and it seems that it should work.  Many people seeing
such a circuit would scoff at the suggestion of actually building and
testing it since it seems "so simple".  The point is, the REASON why
this circuit won't work is NOT something that is taught today in most
BSEE curricula.  It is something that an engineer learns only through
first-person hands-on experience.  And such experience is something
which takes time, involves making mistakes, and is not learned in any
classroom.