[sci.electronics] Help needed with a sick Tectronics 5103N D10 single beam scope

killoran@vlsi.ll.mit.edu (Michael Ian Killoran) (11/08/89)

	Hi!

   I've got a scope that isn't working quite right.  I can get a point in
the middle of the CRT, but it won't move horizontally (no sweep).  Applying
a DC voltage makes the point move up, and a AC voltage makes it move up and
down.  
   From looking inside I found nothing where the there was SUPPOSED to be a
resistor on the power supply board.  The trace from this resistor leads to
a bus which goes up to the CRT board.  On that board there is another resistor
which is discolored and cracked.  Seems like some very(!) good leads on what
is wrong with this scope.  However, the manual I have for this scope only has
the schematics and board photos for the boards in the 'scope' part of the 
scope.  The manual refers to a CRT manual for help in that area.  The hitch
is that I don't HAVE the manual for the CRT.  There is only one board and the
CRT tube itself in this area but this board's description isn't included in
the manual that I have.  
   From what I know so far this scope could be purchased with a number of 
different CRT options.  This is why the scope manual doesn't have the board
layout.  I have the D10 single beam CRT option.  Where can I find a schematic
for this and what will it cost me?  I'm reasonably sure I could fix this scope
if I had it.


		Thanks in advance!   Mike Killoran
killoran@vlsi.ll.mit.edu
killoran@ll-vlsi.arpa