[comp.sys.hp] Hardware flow control from S300

jpederse@encad.Wichita.NCR.COM (John Pedersen) (04/08/88)

I'm trying to get my Series 310 to use hardware flow control and am having no
luck. Heres the setup

Series 310 running HP-UX 5.5 (6.0 is still in the box)
98628 buffered serial interface card (highly recommended)
other assorted cards (4 Meg, DMA, FHPIB)

I am trying to use uucp through an Ungerman Bass 180 NIU to another machine
at the other end of the factory.

When information comes from the NIU at 9600 baud it overrunns the 98628.

According to the HP 4951 protocol analyzer the HP tries to stop the data by
sending XOFF but the NIU is ignoring it, thus data overrun.

The board switches are set as the uucp manual recommends (4 on 5 off Full duplex
modem connection.

I have tried various /dev entries using all combinations of direct/modem
US/CCITT data in/data out. The protocol analyzer still shows the 98628 to be
using XON/XOFF which just doesn't work.

Thus I am heading toward the getty,gettydefs and inittab files to see if I can
find anything there that may set up the serial port, but the outlook doesn't 
look bright. (P.S. the HPUX is the single user version since the machine is
mainly used as an instrument controller, thus I don't think it will have an
entry in inittab as there are no incoming connections only outgoing)

Anyone know the answer and care to point me in the right direction?

-- 
John.Pedersen@Wichita.NCR.COM
NCR Engineering & Manufacturing
EMC Engineering Wichita KS
316-636-8837

rdg@hpfcdc.HP.COM (Rob Gardner) (04/09/88)

> According to the HP 4951 protocol analyzer the HP tries to stop the data by
> sending XOFF but the NIU is ignoring it, thus data overrun.

UUCP turns off flow control for g-protocol, so somebody must be turning
it back on. Are you sure it's not the UB generating the XOFF's? If your
link is (fairly) reliable, why not try f-protocol? It *likes* to
use XON/XOFF.


    Rob Gardner                     {ihnp4!hpfcla,hplabs!hpfcdc}!rdg
    Hewlett Packard                 or rdg%hpfcmr@hplabs.hp.com
    Fort Collins, Colorado          303-229-2048
		80525-9599

		     "Ask me about Home Brewing"

jpederse@encad.Wichita.NCR.COM (John Pedersen) (04/23/88)

If your
|>link is (fairly) reliable, why not try f-protocol? It *likes* to
|>use XON/XOFF.
|>
|>
|>    Rob Gardner                     {ihnp4!hpfcla,hplabs!hpfcdc}!rdg

Thanks Rob, that works great! (I also got the UB straightened out.)


-- 
John.Pedersen@Wichita.NCR.COM
NCR Engineering & Manufacturing
EMC Engineering Wichita KS
316-636-8837