[comp.sys.hp] HP9000/300 and Telebit T2500

warlock@csuchico.edu (John Kennedy) (07/25/90)

  We're trying to correctly hook up a T2500 to a HP9000/300 machine.  Our
current setup lets us dial in (with another Telebit, at least) but it won't
dial out correctly (will dial, but won't connect) and CTS/RTS isn't working.
If you've done this before, please do tell.  Our relevant information is
below:  (Register dump from the modem, gettydefs, inittab, and device)

E1 F1 M1 Q9 T V1 W0 X1 Y0 &P0 &T4     Version GE6.01-T2500
S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006
S10=007 S11=070 S12=050 S18=000 S25=005 S26=000 S38=000 
S41=000 S45:255 S47=004 S48=000 S49=000 
S50=000 S51:005 S52:004 S54:003 S55=000 S56=017 S57=019 S58=003 S59=000 
S61=150 S62=003 S63=001 S64=000 S65=000 S66:001 S67=000 S68=255 S69=000 
S90=000 S91=000 S92=000 S93=008 S94=001 S95:002 S96=001 S97=000 S98=003 
S100=000 S101=000 S102=000 S104=000 S105=001 S106=000 S107=020 
S110=255 S111=255 S112=001 
S121=000 S130:003 S131:001 
S150=000 S151=004 S152=001 S153=001 S154=000 S155=000 
S160=010 S161=020 S162=002 S163=003 S164=007 S255=000 

C19200	# B19200 HUPCL IGNPAR PARENB ICRNL IXON OPOST ONLCR CS7 CREAD
		       ISIG ICANON ECHO ECHOK PARENB ISTRIP IXANY TAB3
		       CLOCAL
	# B19200       SANE CS7 PARENB ISTRIP IXANY TAB3 HUPCL
	#telebit login: #C19200

01:2:respawn:/etc/getty -h tty01 C19200		# Telebit modem

   0 crw--w--w-   1 warlock  staff      1 0x090010 Jul 25 03:08 /dev/tty01

  We're connected to the HP with a straight RS-232c cable (all 25 pins).  I've
also used a cable with only pins 1-8, 20 & 22 connected.  (No difference in
performance).

  My problem (with CTS/RTS, at least) (-: with hardware handshaking seems to be
that RTS isn't being held high by the getty.  Using cu will bring it high,
however.  Looking in the manual under MODEM(7) in the "modem line control
modes" section, I can find a quote that says "When a connection is begun (an
incoming call for a call-in file or an open issued to a call-out file), the
CONTROL are raised and a connection timer is started."  I tried a device with a
minor number of 0x090011 (? -- it's in the UUCP manual in making modem devices)
and it didn't seem to help either.

  Any help at all would be appreciated.  We'd like to start using the modem to
it's fullest potential as soon as possible.

--