robert@psych.psy.uq.oz (Robert Dal Santo) (12/30/89)
This is being posted for a friend. Please E-mail any replies to me and I will pass them on. ---------------------- We have a 3Com 3+Share (version 1.3.1) network running with 35 PC Workstations and two IBM PS/2 model 70s as servers. I have one '70 configured as a print server (two network printers off com1: and lpt1:) and name server, with practically ALL data/programs residing on the other '70. (Ultimately the network is supposed to support 60+ workstations, so the currently installed 35 will stay "on" that second share server). Half the workstations are practically "inactive", as they invoke a standard MS-DOS terminal emulation program (ZSTEM) in the morning from the server and stay "in" that program the rest of the day (using the workstations' com1: RS232 ports to connect to our mini). The other 16+ PC's actively run WordPerfect 5.0 (network version). The workstations are physically scattered over five <= 300 metre lengths of thinwire ethernet, terminating in a 3Com Multiconnect box. Both servers are connected to the first leg. The workstations have 3Com etherlink II ethernet cards, the PS/2's 3Com MCA etherlink boards. We have a recurring problem, in that we "lose" the name service or share service every one or two days. Active workstations get a Network retrying ... Press <Ctrl><Break> to stop message, but NEVER "recover". New logins from previously unused workstations are impossible, with either the name service or share service "not responding". Both servers have the normal "3PLUS 1.3.1 running as a dedicated server" message with no diagnostics or error messages (status.log doesn't log any events at crash time either). Ultimately one or both servers have to be rebooted, although once, after some of the WORKSTATIONS were rebooted, the servers (apparently) DID recover and permit new logins. I've had 3Com advice from two experts (one locally available, another in the distributor's headquarters in Sydney) with both basically giving me "tuning" recommendations, which have alleviated the problem somewhat, but NOT eliminated it. Would anyone on the net be able to help me out? Do you: 1. Know of any bugs/problems with 3Com 3+Share 1.3.1 running on IBM PS/2 model 70's? 2. Believe that 3+Share should be able to (easily?) support 35 workstations on one or two '70 servers? 3. Support my view that a Workstation with the "Network retrying ..." message *should* be able to recover? (I've not yet seen a workstation actually recover and continue work - we've always had to reboot the workstations (after trying to save WordPerfect documents on floppy) and eventually, after a decent period awaiting an automatic resurrection, the servers themselves). I'd greatly appreciate any assistance. ---------------------------------- Robert Dal Santo Phone +61 7 377 4063 (International) Department of Psychology, ARPA: robert%psych.psy.uq.oz@uunet.uu.net University of Queensland, UUCP: ..!uunet!munnari!psych.psy.uq.oz!robert St Lucia, Brisbane, 4067 JANET: psych.psy.uq.oz!robert@ukc AUSTRALIA.