[mod.computers.vax] Has anyone successfully put 2 DEQNAs on a microVAX???

howiegp%cfa1@HARVARD.HARVARD.EDU.UUCP (02/20/87)

I am hoping to use a microVAX with two DEQNA ethernet interfaces to
connect two ethernets together; the microVAX will have full function
routing DECNET and will pass decnet messages between the two LANs.  I cannot
use a bridge in this case, because of incompatibilities between other
protocols in use on the two seperate LANs.

DEC at Colorado claims this configuration should work; so far I've been
unsuccessful.  The second DEQNA does not autoconfigure; when I manually
connect it with SYSGEN, at the address and vector suggested by DEC at Colo,
the system bugchecks with an "unexpected system service exception" in 
NETACP when I try to set the line state on in NCP.  All I've gotten from
DEC is "Hm...should work..."  Am I missing something obvious????

					Howie McCausland
					Center for Astrophysics
					60 Garden St. Cambridge MA. 02138

					617-495-7392
					HOWIEGP@CFA.BITNET

cetron%utah-ced@UTAH-CS.ARPA.UUCP (02/20/87)

1. make sure you changed the hardware address on the second deqna by
	moving jumper W1 over to the second position.  The vector is
	downloaded by the driver, the csr is not.  Moving W1 will move
	the csr from 17774440 to 17774460 which is correct (and fixed.)

2. Make sure W2 is out, and W3 is in... (bus request holdoff enabled, sanity
	timer disabled)

3. make sure both deqna's are up to rev level e1 (stamped on the magenta
	handle)

4. watch both deqna's at power up and verify all led's go off.

5. use the configure command in sysgen to find the correct floating vector
	assignment for xqb.....I wouldn't trust Colorado Springs....

-ed cetron
center for engineering design
univ of utah
cetron@utah-cs.arpa